Changchun Institute of Optics,Fine Mechanics and Physics,CAS
Switching off the SERS signal for highly sensitive and homogeneous detection of glucose by attenuating the electric field of the tips | |
L.Zhang; X.D.Li; Y.Y.Jin; Y.L.Zhang; X.M.Liu; Y.L.Chang | |
2019 | |
发表期刊 | Applied Surface Science |
ISSN | 0169-4332 |
卷号 | 493页码:423-430 |
摘要 | The advances in surface-enhanced Raman scattering (SERS) have resulted in significant improvements for sensing glucose, achieving a highly detecting sensitivity of the order of mu M. Highly sensitive glucose detection, however, is still a challenge due to extremely small Raman scattering cross section of glucose molecules and weak interaction between the molecules and the metal nanoparticles. Here, we designed a novel homogeneous SERS-based nanoplatform composing of the SERS tags and glucose oxidase in aqueous solution for a highly sensitive glucose detection. Adding glucose caused enzymatic oxidation reaction to etch the tip electric field (E) of silver nanotriangle. Thus, the decreased intensity of E was greatly amplified by the change of SERS signal (E-4 dependent), which resulted in an excellent glucose detection limit of 0.4 nM was firstly achieved. Furthermore, the nonlinear relationship between the decreased SERS intensity and the glucose concentrations was reasonably revealed based on theoretical calculations and deeply understanding of the enhancement mechanism, which is very useful in improving the sensitivity and accuracy of trace glucose detection. The as-prepared nanoplatform showed good sensitivity and high selectivity only through observing the SERS intensity change, which is potential for highly sensitive and practical glucose detection for clinical trace analyses. |
关键词 | SERS,Glucose sensing,Homogeneous phase,Silver nanotriangle,enhanced raman-scattering,hot-spots,silver,nanoparticles,hybrid,ag,spectroscopy,platform,oxidase,Chemistry,Materials Science,Physics |
DOI | 10.1016/j.apsusc.2019.07.053 |
收录类别 | SCI ; EI |
语种 | 英语 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/62802 |
专题 | 中国科学院长春光学精密机械与物理研究所 |
推荐引用方式 GB/T 7714 | L.Zhang,X.D.Li,Y.Y.Jin,et al. Switching off the SERS signal for highly sensitive and homogeneous detection of glucose by attenuating the electric field of the tips[J]. Applied Surface Science,2019,493:423-430. |
APA | L.Zhang,X.D.Li,Y.Y.Jin,Y.L.Zhang,X.M.Liu,&Y.L.Chang.(2019).Switching off the SERS signal for highly sensitive and homogeneous detection of glucose by attenuating the electric field of the tips.Applied Surface Science,493,423-430. |
MLA | L.Zhang,et al."Switching off the SERS signal for highly sensitive and homogeneous detection of glucose by attenuating the electric field of the tips".Applied Surface Science 493(2019):423-430. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Switching off the SE(1944KB) | 期刊论文 | 出版稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[L.Zhang]的文章 |
[X.D.Li]的文章 |
[Y.Y.Jin]的文章 |
百度学术 |
百度学术中相似的文章 |
[L.Zhang]的文章 |
[X.D.Li]的文章 |
[Y.Y.Jin]的文章 |
必应学术 |
必应学术中相似的文章 |
[L.Zhang]的文章 |
[X.D.Li]的文章 |
[Y.Y.Jin]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论