摘要 | The error sources that cause the pointing error are briefly analyzed to check whether the spatial static pointing error of a newly developed optical testing target satisfies the design index of 5', and a pointing error model of target mechanism is established by the homogeneous coordinate transformation method. The azimuth and elevation errors of target are calibrated using Leica total station with high precision, and the pointing error of target is further synthesized. The calibrated results reveal that the maximum spatial static pointing error, max, is 275", the mean value, , is 165.9", and the square root, , is 71.5". In order to further improve the pointing accuracy of target, the least square method is used to fit the coefficients in the error model based on the calibrated data samples, and the calculated error models are used as the correction models of azimuth and elevation errors. When the pointing errors are corrected by using the proposed models, the average pointing error values of target mechanism at calibration points and the specific orbit are 21.1" and 20.9", respectively, and the root mean square are 10.6" and 7.2", respectively, which indicates that the static pointing error of the new target is greatly improved after error correction. 2019, Editorial Board of Acta Armamentarii. All right reserved. |
关键词 | Least squares approximations,Error correction,Optical testing,Surface fitting |
DOI | 10.3969/j.issn.1000-1093.2019.05.016 |
URL | 查看原文 |
收录类别 | EI |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/62790 |
专题 | 中国科学院长春光学精密机械与物理研究所 |
推荐引用方式 GB/T 7714 | S.Zhang,X.Xue,Y.Gao,et al. Correction of Static Pointing Error of a Novel Optical Testing Target[J]. Binggong Xuebao/Acta Armamentarii,2019,40(5):1030-1037. |
APA | S.Zhang,X.Xue,Y.Gao,&G.Wang.(2019).Correction of Static Pointing Error of a Novel Optical Testing Target.Binggong Xuebao/Acta Armamentarii,40(5),1030-1037. |
MLA | S.Zhang,et al."Correction of Static Pointing Error of a Novel Optical Testing Target".Binggong Xuebao/Acta Armamentarii 40.5(2019):1030-1037. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Correction of Static(573KB) | 期刊论文 | 出版稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[S.Zhang]的文章 |
[X.Xue]的文章 |
[Y.Gao]的文章 |
百度学术 |
百度学术中相似的文章 |
[S.Zhang]的文章 |
[X.Xue]的文章 |
[Y.Gao]的文章 |
必应学术 |
必应学术中相似的文章 |
[S.Zhang]的文章 |
[X.Xue]的文章 |
[Y.Gao]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论