CIOMP OpenIR
Ultrasensitive label-free optical microfiber coupler biosensor for detection of cardiac troponin I based on interference turning point effect
Zhou, W. C.; Li, K. W.; Wei, Y. L.; Hao, P.; Chi, M. B.; Liu, Y. S.; Wu, Y. H.
2018
发表期刊Biosensors & Bioelectronics
ISSN0956-5663
卷号106页码:99-104
摘要Sensitive detection of cardiac biomarkers is critical for clinical diagnostics of myocardial infarction (MI) while such detection is quite challenging due to the ultra-low concentration of cardiac biomarkers. In this work, a label-free immunosensor based on optical microfiber coupler (OMC) has been developed for the ultrasensitive detection of cardiac troponin I (cTnI), a selective and highly sensitive biomarker of acute myocardial infarction (AMI). CTnI monoclonal antibodies were immobilized on the surface of the fiber through polyelectrolyte layer using layer-by-layer deposition technique. For refractive index sensing characterization, an ultra-high sensitivity of 91777.9 nm/RIU was achieved when the OMC works around the dispersion turning point, which is the highest experimental demonstration in the field of fiber-optic evanescent biosensors. For biosensing, the immunosensor with good specificity showed a linear wavelength shift in the range of 2-10 fg/mL and an ultra-low detection limit of 2 fg/mL. Such immunosensors have huge application potential for the detection of cardiac biomarkers of myocardial infarction due to simple detection scheme, quick response time, ease of handling and miniaturation.
关键词Optical microfiber coupler Biosensor Dispersion turning point Cardiac troponin I Ultrasensitivity Regeneration acute myocardial-infarction refractive-index increments electrochemical immunosensor immunoassay biomarkers nanoparticles diagnosis complex silicon arrays Biophysics Biotechnology & Applied Microbiology Chemistry Electrochemistry Science & Technology - Other Topics
DOI10.1016/j.bios.2018.01.061
收录类别SCI ; EI
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/61211
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
Zhou, W. C.,Li, K. W.,Wei, Y. L.,et al. Ultrasensitive label-free optical microfiber coupler biosensor for detection of cardiac troponin I based on interference turning point effect[J]. Biosensors & Bioelectronics,2018,106:99-104.
APA Zhou, W. C..,Li, K. W..,Wei, Y. L..,Hao, P..,Chi, M. B..,...&Wu, Y. H..(2018).Ultrasensitive label-free optical microfiber coupler biosensor for detection of cardiac troponin I based on interference turning point effect.Biosensors & Bioelectronics,106,99-104.
MLA Zhou, W. C.,et al."Ultrasensitive label-free optical microfiber coupler biosensor for detection of cardiac troponin I based on interference turning point effect".Biosensors & Bioelectronics 106(2018):99-104.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Ultrasensitive label(838KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zhou, W. C.]的文章
[Li, K. W.]的文章
[Wei, Y. L.]的文章
百度学术
百度学术中相似的文章
[Zhou, W. C.]的文章
[Li, K. W.]的文章
[Wei, Y. L.]的文章
必应学术
必应学术中相似的文章
[Zhou, W. C.]的文章
[Li, K. W.]的文章
[Wei, Y. L.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Ultrasensitive label-free optical microfiber c.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。