CIOMP OpenIR
Optical design of double-grating and double wave band spectrometers using a common CCD
Xue, Q. S.; Lu, F. Q.; Duan, M. Z.; Zheng, Y. Q.; Wang, X. H.; Cao, D. S.; Lin, G. Y.; Tian, J. W.
2018
发表期刊Applied Optics
ISSN1559-128X
卷号57期号:23页码:6823-6830
摘要A new type of optical system comprising double-grating and double wave band spectrometers is designed for atmospheric detection. The optical system can bring oxygen A band (758-778 nm) and water vapor absorption band (758-880 nm) on a charge-coupled device (CCD) at the same time for ultrahigh resolution spectrum measurement. Each absorbed band with three observation directions of atmospheric radiation is imaged in different positions of a common CCD. The spectral resolution is less than 0.07 nm in oxygen A band (758-778 nm), and the spectral resolution is less than 0.28 nm in water vapor absorption band (758-880 nm). Three end faces of the optical fiber are on the slit plane for each wave band, and each end face corresponds to an observation angle. The optical fiber core diameter is 600 mu m, the slit width is 25 mu m, and the slit length is 18.4 mm. The principle of smile correction is analyzed. The smile of the Czerny-Turner double-grating spectrometer can be compensated by using the tilt field lens in front of the focal plane. The design results corroborate that the maximum smile of the double-grating spectrometer is 5 mu m and that the approach of correcting smile is effective. The stray light is analyzed, and the approaches of suppressing the stray light are proposed. (C) 2018 Optical Society of America
关键词imaging spectrometer Optics
DOI10.1364/ao.57.006823
收录类别SCI ; EI
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/61092
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
Xue, Q. S.,Lu, F. Q.,Duan, M. Z.,et al. Optical design of double-grating and double wave band spectrometers using a common CCD[J]. Applied Optics,2018,57(23):6823-6830.
APA Xue, Q. S..,Lu, F. Q..,Duan, M. Z..,Zheng, Y. Q..,Wang, X. H..,...&Tian, J. W..(2018).Optical design of double-grating and double wave band spectrometers using a common CCD.Applied Optics,57(23),6823-6830.
MLA Xue, Q. S.,et al."Optical design of double-grating and double wave band spectrometers using a common CCD".Applied Optics 57.23(2018):6823-6830.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Optical design of do(2678KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Xue, Q. S.]的文章
[Lu, F. Q.]的文章
[Duan, M. Z.]的文章
百度学术
百度学术中相似的文章
[Xue, Q. S.]的文章
[Lu, F. Q.]的文章
[Duan, M. Z.]的文章
必应学术
必应学术中相似的文章
[Xue, Q. S.]的文章
[Lu, F. Q.]的文章
[Duan, M. Z.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Optical design of double-grating and double wa.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。