CIOMP OpenIR
Effect of distances between lens and sample surface on laser-induced breakdown spectroscopy with spatial confinement
Jiang, Z. H.; Shao, J. F.; Wang, T. F.; Guo, J.; Zhang, D.; Chen, A. M.; Jin, M. X.
2018
发表期刊Plasma Science & Technology
ISSN1009-0630
卷号20期号:8页码:8
摘要Spatial confinement can significantly enhance the spectral intensity of laser-induced plasma in air. It is attributed to the compression of plasma plume by the reflected shockwave. In addition, optical emission spectroscopy of laser-induced plasma can also be affected by the distance between lens and sample surface. In order to obtain the optimized spectral intensity, the distance must be considered. In this work, spatially confined laser-induced silicon plasma by using a Nd: YAG nanosecond laser at different distances between lens and sample surface was investigated. The laser energies were 12 mJ, 16 mJ, 20 mJ, and 24 mJ. All experiments were carried out in an atmospheric environment. The results indicated that the intensity of Si (I) 390.55 nm line firstly rose and then dropped with the increase of lens-to-sample distance. Moreover, the spectral peak intensity with spatial confinement was higher than that without spatial confinement. The enhancement ratio was approximately 2 when laser energy was 24 mJ.
关键词laser-induced breakdown spectroscopy LIBS spatial confinement distance of lens-to-sample signal enhancement optical-emission induced plasmas cu plasma ablation enhancement spectrometry spectra argon Physics
DOI10.1088/2058-6272/aabc5e
收录类别SCI ; EI
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/60964
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
Jiang, Z. H.,Shao, J. F.,Wang, T. F.,et al. Effect of distances between lens and sample surface on laser-induced breakdown spectroscopy with spatial confinement[J]. Plasma Science & Technology,2018,20(8):8.
APA Jiang, Z. H..,Shao, J. F..,Wang, T. F..,Guo, J..,Zhang, D..,...&Jin, M. X..(2018).Effect of distances between lens and sample surface on laser-induced breakdown spectroscopy with spatial confinement.Plasma Science & Technology,20(8),8.
MLA Jiang, Z. H.,et al."Effect of distances between lens and sample surface on laser-induced breakdown spectroscopy with spatial confinement".Plasma Science & Technology 20.8(2018):8.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Effect of distances (2318KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Jiang, Z. H.]的文章
[Shao, J. F.]的文章
[Wang, T. F.]的文章
百度学术
百度学术中相似的文章
[Jiang, Z. H.]的文章
[Shao, J. F.]的文章
[Wang, T. F.]的文章
必应学术
必应学术中相似的文章
[Jiang, Z. H.]的文章
[Shao, J. F.]的文章
[Wang, T. F.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Effect of distances between lens and sample su.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。