Changchun Institute of Optics,Fine Mechanics and Physics,CAS
Effect of distances between lens and sample surface on laser-induced breakdown spectroscopy with spatial confinement | |
Jiang, Z. H.; Shao, J. F.; Wang, T. F.; Guo, J.; Zhang, D.; Chen, A. M.; Jin, M. X. | |
2018 | |
发表期刊 | Plasma Science & Technology |
ISSN | 1009-0630 |
卷号 | 20期号:8页码:8 |
摘要 | Spatial confinement can significantly enhance the spectral intensity of laser-induced plasma in air. It is attributed to the compression of plasma plume by the reflected shockwave. In addition, optical emission spectroscopy of laser-induced plasma can also be affected by the distance between lens and sample surface. In order to obtain the optimized spectral intensity, the distance must be considered. In this work, spatially confined laser-induced silicon plasma by using a Nd: YAG nanosecond laser at different distances between lens and sample surface was investigated. The laser energies were 12 mJ, 16 mJ, 20 mJ, and 24 mJ. All experiments were carried out in an atmospheric environment. The results indicated that the intensity of Si (I) 390.55 nm line firstly rose and then dropped with the increase of lens-to-sample distance. Moreover, the spectral peak intensity with spatial confinement was higher than that without spatial confinement. The enhancement ratio was approximately 2 when laser energy was 24 mJ. |
关键词 | laser-induced breakdown spectroscopy LIBS spatial confinement distance of lens-to-sample signal enhancement optical-emission induced plasmas cu plasma ablation enhancement spectrometry spectra argon Physics |
DOI | 10.1088/2058-6272/aabc5e |
收录类别 | SCI ; EI |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/60964 |
专题 | 中国科学院长春光学精密机械与物理研究所 |
推荐引用方式 GB/T 7714 | Jiang, Z. H.,Shao, J. F.,Wang, T. F.,et al. Effect of distances between lens and sample surface on laser-induced breakdown spectroscopy with spatial confinement[J]. Plasma Science & Technology,2018,20(8):8. |
APA | Jiang, Z. H..,Shao, J. F..,Wang, T. F..,Guo, J..,Zhang, D..,...&Jin, M. X..(2018).Effect of distances between lens and sample surface on laser-induced breakdown spectroscopy with spatial confinement.Plasma Science & Technology,20(8),8. |
MLA | Jiang, Z. H.,et al."Effect of distances between lens and sample surface on laser-induced breakdown spectroscopy with spatial confinement".Plasma Science & Technology 20.8(2018):8. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Effect of distances (2318KB) | 期刊论文 | 出版稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论