Analysis and correction for measurement error of edge sensors caused by deformation of guide flexure applied in the Thirty Meter Telescope SSA | |
Cao, H. F.; Zhang, J. X.; Yang, F.; An, Q. C.; Zhao, H. C.; Guo, P. | |
2018 | |
发表期刊 | Applied Optics |
ISSN | 1559-128X |
卷号 | 57期号:13页码:3401-3409 |
摘要 | The Thirty Meter Telescope (TMT) project will design and build a 30-m-diameter telescope for research in astronomy in visible and infrared wavelengths. The primary mirror of TMT is made up of 492 hexagonal mirror segments under active control. The highly segmented primary mirror will utilize edge sensors to align and stabilize the relative piston, tip, and tilt degrees of segments. The support systemassembly (SSA) of the segmented mirror utilizes a guide flexure to decouple the axial support and lateral support, while its deformation will cause measurement error of the edge sensor. We have analyzed the theoretical relationship between the segment movement and the measurement value of the edge sensor. Further, we have proposed an error correction method with amatrix. The correction process and the simulation results of the edge sensor will be described in this paper. (C) 2018 Optical Society of America |
关键词 | primary mirror active control e-elt vibrations design system tmt Optics |
DOI | 10.1364/ao.57.003401 |
收录类别 | SCI ; EI |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/60909 |
专题 | 中国科学院长春光学精密机械与物理研究所 |
推荐引用方式 GB/T 7714 | Cao, H. F.,Zhang, J. X.,Yang, F.,et al. Analysis and correction for measurement error of edge sensors caused by deformation of guide flexure applied in the Thirty Meter Telescope SSA[J]. Applied Optics,2018,57(13):3401-3409. |
APA | Cao, H. F.,Zhang, J. X.,Yang, F.,An, Q. C.,Zhao, H. C.,&Guo, P..(2018).Analysis and correction for measurement error of edge sensors caused by deformation of guide flexure applied in the Thirty Meter Telescope SSA.Applied Optics,57(13),3401-3409. |
MLA | Cao, H. F.,et al."Analysis and correction for measurement error of edge sensors caused by deformation of guide flexure applied in the Thirty Meter Telescope SSA".Applied Optics 57.13(2018):3401-3409. |