Sensitivity analysis of different scan arcs for swing arm profilometer test
Xiong, Ling; Luo, Xiao; Qi, Erhui; Zhang, Feng; Xue, Donglin; Zhang, Xuejun
2018
发表期刊Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering
ISSN10072276
卷号47期号:2
摘要To analyze test errors induced from system noise of swing arm profilometer (SAP) testing large aperture off-axis aspherics with different scan arcs, based on the Monte Carlo method, the simulation test model was built with different scan patterns from 8 arcs to 120 arcs. To evaluate the test sensitivity, test errors induced from system noise was fitted by Zernike polynomial. The low order test errors were reduced rapidly as scan arcs increased from 8 arcs to 39 arcs, and reduced slowly from 40 arcs to 70 arcs, and kept almost the same from 71 arcs to 120 arcs. As an experiment, a 1500 mm off-axis aspheric mirror was tested by SAP scanning in 36 arcs, 72 arcs and 96 arcs respectively. The surface test error of 36 arcs are much larger with result of 7.73 m in Peak-Valley (PV) and 0.68 m in Root-Mean-Square (RMS). The surface test error of 72 arcs and 96 arcs are much close with result of 5.755 m PV, 0.568 m RMS and 5.612 m PV, 0.569 m RMS respectively. So the simulation results were verified and provided a guide for the scan line selection for SAP testing large off-axis aspherics. 2018, Editorial Board of Journal of Infrared and Laser Engineering. All right reserved.
关键词Testing Aspherics Errors Monte Carlo methods Profilometry Sensitivity analysis
DOI10.3788/IRLA201847.0217003
收录类别EI
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/60805
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
Xiong, Ling,Luo, Xiao,Qi, Erhui,et al. Sensitivity analysis of different scan arcs for swing arm profilometer test[J]. Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering,2018,47(2).
APA Xiong, Ling,Luo, Xiao,Qi, Erhui,Zhang, Feng,Xue, Donglin,&Zhang, Xuejun.(2018).Sensitivity analysis of different scan arcs for swing arm profilometer test.Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering,47(2).
MLA Xiong, Ling,et al."Sensitivity analysis of different scan arcs for swing arm profilometer test".Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering 47.2(2018).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Sensitivity analysis(724KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Xiong, Ling]的文章
[Luo, Xiao]的文章
[Qi, Erhui]的文章
百度学术
百度学术中相似的文章
[Xiong, Ling]的文章
[Luo, Xiao]的文章
[Qi, Erhui]的文章
必应学术
必应学术中相似的文章
[Xiong, Ling]的文章
[Luo, Xiao]的文章
[Qi, Erhui]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Sensitivity analysis of different scan arcs fo.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。