CIOMP OpenIR
Fabrication and flatness error analysis of a low-stepped mirror in a static Fourier transform infrared spectrometer
Zhang, M.; Liang, J. Q.; Liang, Z. Z.; Lv, J. G.; Qin, Y. X.; Wang, W. B.
2018
发表期刊Journal of Optical Technology
ISSN1070-9762
卷号85期号:9页码:582-589
摘要In this study, we propose a Fourier transform infrared spectrometer based on stepped mirrors, which realize static. As the core component of the spectrometer, the low-stepped mirror's structural parameters significantly affect the instrument performance. In order to successfully fabricate a low-stepped mirror with a large area and submicrometer height, we propose a method involving multiple depositions accompanied by a 50% reduction in thickness at every iteration, which can precisely control the accuracy, consistency, and uniformity of the step height. After that, we fabricate a low-stepped mirror consisting of 32 stages and with a step height of 625 run. Through theoretical calculation and simulation analysis, the influence of the step's flatness error on the recovery spectrum is obtained. By increasing the substrate thickness of the stepped mirror, we can reduce the stress of the thin film. We perform experiments using the low-stepped mirror. The low-stepped mirror was incorporated into the Fourier transform infrared spectrometer, and we performed experiments to obtain the spectrum of acetonitrile liquid. The spectrogram of the acetonitrile is obtained by processing the interferogram. (C) 2018 Optical Society of America
关键词moving parts interferometers spectroscopy Optics
DOI10.1364/jot.85.000582
收录类别SCI
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/60661
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
Zhang, M.,Liang, J. Q.,Liang, Z. Z.,et al. Fabrication and flatness error analysis of a low-stepped mirror in a static Fourier transform infrared spectrometer[J]. Journal of Optical Technology,2018,85(9):582-589.
APA Zhang, M.,Liang, J. Q.,Liang, Z. Z.,Lv, J. G.,Qin, Y. X.,&Wang, W. B..(2018).Fabrication and flatness error analysis of a low-stepped mirror in a static Fourier transform infrared spectrometer.Journal of Optical Technology,85(9),582-589.
MLA Zhang, M.,et al."Fabrication and flatness error analysis of a low-stepped mirror in a static Fourier transform infrared spectrometer".Journal of Optical Technology 85.9(2018):582-589.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Fabrication and flat(2007KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zhang, M.]的文章
[Liang, J. Q.]的文章
[Liang, Z. Z.]的文章
百度学术
百度学术中相似的文章
[Zhang, M.]的文章
[Liang, J. Q.]的文章
[Liang, Z. Z.]的文章
必应学术
必应学术中相似的文章
[Zhang, M.]的文章
[Liang, J. Q.]的文章
[Liang, Z. Z.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Fabrication and flatness error analysis of a l.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。