Changchun Institute of Optics,Fine Mechanics and Physics,CAS
Design of a compact spectrometer under grazing incidence conditions for near-edge X-ray absorption spectroscopy;X | |
Chen, Chen-Xi-Yang; Jin, Chun-Shui; Wang, Jun; Xie, Yao | |
2018 | |
发表期刊 | Chinese Optics |
ISSN | 20951531 |
卷号 | 11期号:2页码:265-278 |
摘要 | Near edge X-ray absorption fine structure(NEXAFS) spectrum contains the local structure information of the absorbing atoms. Due to its wide range of applications and high sensitivity, it has become an important method to study the structure of materials. In order to study the NEXAFS spectrum of carbon in organic substances, a design of a compact spectrometer under grazing incidence conditions is presented, based on a laser-produced plasma source using a gas target. An aberration corrected flat-field grating and a CCD camera are used to detect the spectrum. To achieve the high precision adjustment of the incident angle of the grating, an optimized scheme where the incident angle is 88.6 has been given. Using ray tracing, the resolution of the spectrometer is analyzed. It is about 666 at 4.4 nm in the wavelength range of 2-5 nm. From the influence of each parameter error on the image width, it is found that the error of the incident angle is the most sensitive, and using the optimized assembly scheme is able to achieve the high accuracy adjustment of the incident angle. The performance of the spectrometer has been tested using the nitrogen plasma spectrum, and the results show that the resolution reaches the design index. 2018, China Science Publishing & Media LTD. All right reserved. |
关键词 | Spectrometers CCD cameras Laser produced plasmas Nitrogen plasma Optical resolving power Organic carbon Organic lasers Ray tracing X ray absorption spectroscopy |
DOI | 10.3788/CO.20181102.0265 |
收录类别 | EI |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/60611 |
专题 | 中国科学院长春光学精密机械与物理研究所 |
推荐引用方式 GB/T 7714 | Chen, Chen-Xi-Yang,Jin, Chun-Shui,Wang, Jun,et al. Design of a compact spectrometer under grazing incidence conditions for near-edge X-ray absorption spectroscopy;X[J]. Chinese Optics,2018,11(2):265-278. |
APA | Chen, Chen-Xi-Yang,Jin, Chun-Shui,Wang, Jun,&Xie, Yao.(2018).Design of a compact spectrometer under grazing incidence conditions for near-edge X-ray absorption spectroscopy;X.Chinese Optics,11(2),265-278. |
MLA | Chen, Chen-Xi-Yang,et al."Design of a compact spectrometer under grazing incidence conditions for near-edge X-ray absorption spectroscopy;X".Chinese Optics 11.2(2018):265-278. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Design of a compact (2513KB) | 期刊论文 | 出版稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论