Changchun Institute of Optics,Fine Mechanics and Physics,CAS
Correction of temperature measurement accuracy affected by internal temperature rise in uncooled thermal imager | |
Zhang, Yan-Chao![]() ![]() | |
2018 | |
发表期刊 | Chinese Optics |
ISSN | 20951531 |
卷号 | 11期号:4页码:669-676 |
摘要 | With the increase of the operating time of uncooled infrared thermal imager, the internal devices and mechanical structures accumulate more and more heat, and the thermal radiation caused by the temperature rise is bound to have serious effects on the accuracy of the thermal imager. Therefore, in order to achieve accurate temperature measurement of the thermal imager, it is necessary to correct the internal temperature influencing factors. This paper evaluates and models the three factors that affect the accuracy of temperature measurement: the barrel radiation temperature, the temperature of the target surface of the detector, and the cumulative working time of the thermal imager, and evaluates the relationship among them. Finally, the temperature measurement of the thermal imager is corrected according to the data model. The results show that under the laboratory conditions, the temperature accuracy of the uncooled infrared camera can be controlled within 1 , and its stability can be controlled within 0.5 . The corrected temperature is basically independent of the internal temperature rise, thus effectively improves the stability, repeatability, and accuracy of the temperature measurement of the uncooled thermal imager. 2018, China Science Publishing & Media LTD. All right reserved. |
关键词 | Temperature measurement Image enhancement Radiation effects |
DOI | 10.3788/CO.20181104.0669 |
收录类别 | EI |
引用统计 | 正在获取...
|
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/60601 |
专题 | 中国科学院长春光学精密机械与物理研究所 |
推荐引用方式 GB/T 7714 | Zhang, Yan-Chao,Gao, Ce,Liu, Jian-Zhuo,et al. Correction of temperature measurement accuracy affected by internal temperature rise in uncooled thermal imager[J]. Chinese Optics,2018,11(4):669-676. |
APA | Zhang, Yan-Chao,Gao, Ce,Liu, Jian-Zhuo,Wang, Bo,&Yang, Shuai.(2018).Correction of temperature measurement accuracy affected by internal temperature rise in uncooled thermal imager.Chinese Optics,11(4),669-676. |
MLA | Zhang, Yan-Chao,et al."Correction of temperature measurement accuracy affected by internal temperature rise in uncooled thermal imager".Chinese Optics 11.4(2018):669-676. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Correction of temper(2361KB) | 期刊论文 | 出版稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论