Changchun Institute of Optics,Fine Mechanics and Physics,CAS
Correction for Effect of Calibration Error on Accuracy of Co-Phasing Error Detection of Dispersed Fringe | |
Zhang, Chunyue; Xu, Shuyan; Xu, Boqian; Qi, Xin; Ju, Guohao | |
2018 | |
发表期刊 | Guangxue Xuebao/Acta Optica Sinica |
ISSN | 2532239 |
卷号 | 38期号:7 |
摘要 | The dispersed fringe co-phasing error detection technology needs a certain method to analyze and process the acquired dispersed fringe image to obtain the corresponding piston error value. Compared with other dispersed fringe image processing methods, the main peak position extraction method can be applied to the detection of piston error in large range or in small range within one wavelength. However, the detection accuracy of the method is very sensitive to the calibration error in the central line position of the dispersed fringe. To modify the effect of this calibration error, this paper firstly proposes a self-adaptive extraction method for fringe central line position based on the analysis of the influence of the piston error on the diffraction pattern of double rectangle hole. Based on this, combined with the basic principle of the main peak position extraction method, a method of correcting the influence of fringe central line calibration error is proposed. Finally, an experimental light path is built to verify the effectiveness of the proposed correction method. The experimental results show that the proposed method can achieve a measurement accuracy of less than 30 nm in the presence of the central line calibration error, which is greatly improved compared to the accuracy before correction. This method effectively improves the anti-jamming capability and engineering practicality of the main peak position extraction method. 2018, Chinese Lasers Press. All right reserved. |
关键词 | Error detection Calibration Extraction Image processing Imaging systems Pistons |
DOI | 10.3788/AOS201838.0711003 |
收录类别 | EI |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/60600 |
专题 | 中国科学院长春光学精密机械与物理研究所 |
推荐引用方式 GB/T 7714 | Zhang, Chunyue,Xu, Shuyan,Xu, Boqian,et al. Correction for Effect of Calibration Error on Accuracy of Co-Phasing Error Detection of Dispersed Fringe[J]. Guangxue Xuebao/Acta Optica Sinica,2018,38(7). |
APA | Zhang, Chunyue,Xu, Shuyan,Xu, Boqian,Qi, Xin,&Ju, Guohao.(2018).Correction for Effect of Calibration Error on Accuracy of Co-Phasing Error Detection of Dispersed Fringe.Guangxue Xuebao/Acta Optica Sinica,38(7). |
MLA | Zhang, Chunyue,et al."Correction for Effect of Calibration Error on Accuracy of Co-Phasing Error Detection of Dispersed Fringe".Guangxue Xuebao/Acta Optica Sinica 38.7(2018). |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Correction for Effec(3465KB) | 期刊论文 | 出版稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论