CIOMP OpenIR
A pressure-driven gas-diffusionpermeation micropump for self-activated sample transport in an extreme micro-environment
Wu, W. M.
2018
发表期刊Analyst
ISSN0003-2654
卷号143期号:20页码:4819-4835
摘要The micropump is the most important functional unit of a micro total analysis system (TAS). An ideal microfluidics system should adopt simple, stable, robust, inexpensive, and integrated on-chip strategies to transport samples for downstream applications, with little or no external energy consumption and limited manual intervention. Nevertheless, it remains a key challenge for traditional micropumps to be directly integrated into self-contained and disposable TAS for velocity-stable and passive sample transport. The best way to assess the capability of passive micropumps is to evaluate their pumping performance in extreme environments, e.g. a 3D configurated microchannel instead of a 2D configuration, high temperature conditions instead of at room temperature, a long microchannel instead of short microchannel, a complex topological microsystem (e.g. a microvascular network interconnecting multiple inlets and outlets) instead of a simple topological microsystem (e.g. a one-directional microchannel connecting only one inlet and one outlet), and multi-phase microdroplet transport instead of single-phase plug transport. In this review, a novel micropumping methodology - a pressure-driven gas-diffusion/permeation micropump - is described, which is the first review paper dedicated to this subject. A comprehensive overview is provided for comparison between this novel micropumping methodology and traditional passive micropumps, especially for applications in stable velocity control in the aforementioned extreme environments. Compared with mainstream conventional micropumps, we confirm that pressure-driven gas-diffusion/permeation micropumps combine a number of superior properties all into one device, such as small size, simple structure, without the need for microfabrication procedures or external power consumption, strong transport capacity, homogeneous flow velocity, delivery capacity for both multi-phase microdroplets and single-phase plugs, long-distance transport, persistent pumping for both 3D microchannels and complex topological microsystems (e.g. a biomimetic microvasculature), low cost, ease of microdevice integration, bubble suppression and amazing stability at high temperatures. An advanced outlook and perspectives for the future development of this novel micropump are also discussed, which may serve as a starting point for researchers in the microfluidics fields to harness pressure-driven gas-diffusion/permeation micropumps for downstream applications.
关键词polymerase-chain-reaction capillary-driven microfluidic chip single heater piezoelectric micropump flow pump pcr liquid microdevice Chemistry
DOI10.1039/c8an01120f
收录类别SCI
引用统计
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/60563
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
Wu, W. M.. A pressure-driven gas-diffusionpermeation micropump for self-activated sample transport in an extreme micro-environment[J]. Analyst,2018,143(20):4819-4835.
APA Wu, W. M..(2018).A pressure-driven gas-diffusionpermeation micropump for self-activated sample transport in an extreme micro-environment.Analyst,143(20),4819-4835.
MLA Wu, W. M.."A pressure-driven gas-diffusionpermeation micropump for self-activated sample transport in an extreme micro-environment".Analyst 143.20(2018):4819-4835.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
A pressure-driven ga(4033KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Wu, W. M.]的文章
百度学术
百度学术中相似的文章
[Wu, W. M.]的文章
必应学术
必应学术中相似的文章
[Wu, W. M.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: A pressure-driven gas-diffusionpermeation micr.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。