Thermal calibration of a tri-axial MEMS gyroscope based on Parameter-Interpolation method | |
Zhang, B. Q.; H. R. Chu; T. T. Sun and L. H. Guo | |
2017 | |
发表期刊 | Sensors and Actuators a-Physical |
卷号 | 261 |
摘要 | The error of a MEMS gyroscope is highly dependent on the ambient temperature. Traditionally, it is modeled with polynomials, which cannot achieve sufficient accuracy. In order to solve this problem, a Parameter-Interpolation method is proposed to model and calibrate the deterministic error of a MEMS gyroscope. First, the establishment of a MEMS gyroscope's error model and the calibration methods are discussed. Based on the traditional method, we come up with the Parameter-Interpolation (PI) model. Its parameters vary with temperature and each group of parameters is saved separately. The gyroscope is calibrated through interpolation. Then, we design a multi-position experiment test using a thermal turntable to test the traditional and the Parameter-Interpolation (PI) methods. Finally, we process the data collected in the experiments and compare the results of these two methods. Results show that both methods are valid to improve the accuracy of a MEMS gyroscope but the Parameter-Interpolation (PI) method is more effective. (C) 2017 Elsevier B.V. All rights reserved. |
收录类别 | sci ; ei |
语种 | 英语 |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/59415 |
专题 | 中科院长春光机所知识产出 |
推荐引用方式 GB/T 7714 | Zhang, B. Q.,H. R. Chu,T. T. Sun and L. H. Guo. Thermal calibration of a tri-axial MEMS gyroscope based on Parameter-Interpolation method[J]. Sensors and Actuators a-Physical,2017,261. |
APA | Zhang, B. Q.,H. R. Chu,&T. T. Sun and L. H. Guo.(2017).Thermal calibration of a tri-axial MEMS gyroscope based on Parameter-Interpolation method.Sensors and Actuators a-Physical,261. |
MLA | Zhang, B. Q.,et al."Thermal calibration of a tri-axial MEMS gyroscope based on Parameter-Interpolation method".Sensors and Actuators a-Physical 261(2017). |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Thermal calibration (7765KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |