CIOMP OpenIR  > 中科院长春光机所知识产出
Internal Stray Radiation Measurement for Cooled Infrared Imaging Systems Using Ambient Temperature
Tian, Q.; S. Chang; F. He and Y. Qiao
2017
发表期刊Guangxue Xuebao/Acta Optica Sinica
卷号37期号:7
摘要The suppression level of internal stray radiation is a key indicator to evaluate infrared imaging systems. Being related to ambient temperature, the internal stray radiation must be measured at multiple ambient temperatures, and the measurement has such disadvantages as high cost, long duration and high demand for experimental setups. To solve these problems, the effect of ambient temperature on internal stray radiation is studied by building a multi-integral time calibration model, and a method is proposed to measure internal stray radiation of cooled infrared imaging systems using ambient temperature. In this method, the influence of internal factors of the detector on the system output is obtained by calibrating the cooled infrared detector. Combining the calibration results of the infrared imaging system under a certain ambient temperature, the quantitative relation between internal stray radiation and ambient temperature is resolved. Then the internal stray radiation can be calculated at arbitrary integration times and ambient temperatures. The effectiveness of the proposed method is verified by radiometric calibration experiments. Experimental results indicate that, with the proposed method, high-precision measurement of internal stray radiation in cooled infrared imaging systems can be achieved. 2017, Chinese Lasers Press. All right reserved.
收录类别ei
语种中文
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/59225
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Tian, Q.,S. Chang,F. He and Y. Qiao. Internal Stray Radiation Measurement for Cooled Infrared Imaging Systems Using Ambient Temperature[J]. Guangxue Xuebao/Acta Optica Sinica,2017,37(7).
APA Tian, Q.,S. Chang,&F. He and Y. Qiao.(2017).Internal Stray Radiation Measurement for Cooled Infrared Imaging Systems Using Ambient Temperature.Guangxue Xuebao/Acta Optica Sinica,37(7).
MLA Tian, Q.,et al."Internal Stray Radiation Measurement for Cooled Infrared Imaging Systems Using Ambient Temperature".Guangxue Xuebao/Acta Optica Sinica 37.7(2017).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Internal Stray Radia(472KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Tian, Q.]的文章
[S. Chang]的文章
[F. He and Y. Qiao]的文章
百度学术
百度学术中相似的文章
[Tian, Q.]的文章
[S. Chang]的文章
[F. He and Y. Qiao]的文章
必应学术
必应学术中相似的文章
[Tian, Q.]的文章
[S. Chang]的文章
[F. He and Y. Qiao]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Internal Stray Radiation Measurement.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。