Changchun Institute of Optics,Fine Mechanics and Physics,CAS
High-efficiency non-uniformity correction for wide dynamic linear infrared radiometry system | |
Li, Z.; Y. Yu; Q. J. Tian; S. T. Chang; F. Y. He; Y. H. Yin and Y. F. Qiao | |
2017 | |
发表期刊 | Infrared Physics & Technology |
卷号 | 85 |
摘要 | Several different integration times are always set for a wide dynamic linear and continuous variable integration time infrared radiometry system, therefore, traditional calibration-based non-uniformity correction (NUC) are usually conducted one by one, and furthermore, several calibration sources required, consequently makes calibration and process of NUC time-consuming. In this paper, the difference of NUC coefficients between different integration times have been discussed, and then a novel NUC method called high-efficiency NUC, which combines the traditional calibration-based non-uniformity correction, has been proposed. It obtains the correction coefficients of all integration times in whole linear dynamic rangesonly by recording three different images of a standard blackbody. Firstly, mathematical procedure of the proposed non-uniformity correction method is validated and then its performance is demonstrated by a 400 mm diameter ground-based infrared radiometry system. Experimental results show that the mean value of Normalized Root Mean Square (NRMS) is reduced from 3.78% to 0.24% by the proposed method. In addition, the results at 4 ms and 70 degrees C prove that this method has a higher accuracy compared with traditional calibration-based NUC. In the meantime, at other integration time and temperature there is still a good correction effect. Moreover, it greatly reduces the number of correction time and temperature sampling point, and is characterized by good real-time performance and suitable for field measurement. (C) 2017 Published by Elsevier B.V. |
收录类别 | sci ; ei |
语种 | 英语 |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/59038 |
专题 | 中科院长春光机所知识产出 |
推荐引用方式 GB/T 7714 | Li, Z.,Y. Yu,Q. J. Tian,et al. High-efficiency non-uniformity correction for wide dynamic linear infrared radiometry system[J]. Infrared Physics & Technology,2017,85. |
APA | Li, Z.,Y. Yu,Q. J. Tian,S. T. Chang,F. Y. He,&Y. H. Yin and Y. F. Qiao.(2017).High-efficiency non-uniformity correction for wide dynamic linear infrared radiometry system.Infrared Physics & Technology,85. |
MLA | Li, Z.,et al."High-efficiency non-uniformity correction for wide dynamic linear infrared radiometry system".Infrared Physics & Technology 85(2017). |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
High-efficiency non-(2100KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Li, Z.]的文章 |
[Y. Yu]的文章 |
[Q. J. Tian]的文章 |
百度学术 |
百度学术中相似的文章 |
[Li, Z.]的文章 |
[Y. Yu]的文章 |
[Q. J. Tian]的文章 |
必应学术 |
必应学术中相似的文章 |
[Li, Z.]的文章 |
[Y. Yu]的文章 |
[Q. J. Tian]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论