CIOMP OpenIR  > 中科院长春光机所知识产出
Baseline Fitting of Partial Least Squares for Oxygen A Absorption Band
Li, J.; M. Zhang and D. Zhang
2017
发表期刊Zhongguo Jiguang/Chinese Journal of Lasers
卷号44期号:8
摘要In order to research the relation between self-emission spectrum and transmittance of target at oxygen A-band, the method for fitting the baseline of oxygen A-band spectrum based on the partial least square regression (PLSR) is proposed according to the transmittance calculation method. The experimental system is set up to verify the accuracy of baseline fitting. Firstly, the calculation method of oxygen A-band average transmittance is given according to the blackbody radiation theory. The spectrum of the target to be measured is used as study object. The PLSR is used to fit the baseline of the target to be measured at oxygen A-band according to the out-of-band data. For the sake of improving the fitting accuracy, the singular point of measurement is eliminated. The baseline fitting uncertainty is used to evaluate the fitting accuracy of PLSR. In order to verify the accuracy of this method, the spectra with different distances and different resolutions at the same distance are measured in the range of 0~130 m using the halogen light. These spectra are fitted and each standard deviation is analyzed. The results show that the average standard deviation is 0.23% with different resolutions at the same distance. The baseline fitting uncertainty becomes smaller and signal-to-noise ratio increases with the resolution reducing. In addition, the baseline fitting uncertainty is related to the resolution of the test equipment. The higher the resolution is, the larger the uncertainty of out-of-band data baseline fitting becomes, whereas, the smaller the out-of-band baseline fitting becomes. 2017, Chinese Lasers Press. All right reserved.
收录类别ei
语种中文
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/59000
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Li, J.,M. Zhang and D. Zhang. Baseline Fitting of Partial Least Squares for Oxygen A Absorption Band[J]. Zhongguo Jiguang/Chinese Journal of Lasers,2017,44(8).
APA Li, J.,&M. Zhang and D. Zhang.(2017).Baseline Fitting of Partial Least Squares for Oxygen A Absorption Band.Zhongguo Jiguang/Chinese Journal of Lasers,44(8).
MLA Li, J.,et al."Baseline Fitting of Partial Least Squares for Oxygen A Absorption Band".Zhongguo Jiguang/Chinese Journal of Lasers 44.8(2017).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Baseline Fitting.pdf(607KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Li, J.]的文章
[M. Zhang and D. Zhang]的文章
百度学术
百度学术中相似的文章
[Li, J.]的文章
[M. Zhang and D. Zhang]的文章
必应学术
必应学术中相似的文章
[Li, J.]的文章
[M. Zhang and D. Zhang]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Baseline Fitting.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。