CIOMP OpenIR  > 中科院长春光机所知识产出
Imaging quality evaluation method of pixel coupled electro-optical imaging system
He, X.; L. Yuan; C. Q. Jin and X. H. Zhang
2017
发表期刊Optics Communications
卷号399
摘要With advancements in high-resolution imaging optical fiber bundle fabrication technology, traditional photoelectric imaging system have become "flexible" with greatly reduced volume and weight. However, traditional image quality evaluation models are limited by the coupling discrete sampling effect of fiber-optic image bundles and charge-coupled device (CCD) pixels. This limitation substantially complicates the design, optimization, assembly, and evaluation image quality of the coupled discrete sampling imaging system. Based on the transfer process of grayscale cosine distribution optical signal in the fiber-optic image bundle and CCD, a mathematical model of coupled modulation transfer function (coupled-MTF) is established. This model can be used as a basis for following studies on the convergence and periodically oscillating characteristics of the function. We also propose the concept of the average coupled-MTF, which is consistent with the definition of traditional MTF. Based on this concept, the relationships among core distance, core layer radius, and average coupled-MTF are investigated. Results show that the coupled-MTF oscillation converges to a fixed value when the deviation between a spatial frequency of input signal and Nyquist frequency is 1% and when the total number of pixels in the coupled system is more than 1000. The minimal frequency deviation corresponds to the slow velocity of the oscillational convergent. The oscillation amplitude of coupled-MTF differs in tangential and sagittal directions in a manner related to the corresponding pixel coupling error. The coupled-MTF periodically oscillates with the alignment error between the coupled pixel. One cycle is equivalent to the diameter of fiber cladding. The observation from the simulations further reveal that the distance between adjacent fiber cores and the dimension of core layer are directly related to the system imaging quality and the signal-to-noise ratio. Moreover, the average coupled-MTF can be used to quantitatively describe the function of related parameters and the imaging quality of the system.
收录类别sci ; ei
语种英语
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/58941
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
He, X.,L. Yuan,C. Q. Jin and X. H. Zhang. Imaging quality evaluation method of pixel coupled electro-optical imaging system[J]. Optics Communications,2017,399.
APA He, X.,L. Yuan,&C. Q. Jin and X. H. Zhang.(2017).Imaging quality evaluation method of pixel coupled electro-optical imaging system.Optics Communications,399.
MLA He, X.,et al."Imaging quality evaluation method of pixel coupled electro-optical imaging system".Optics Communications 399(2017).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Imaging quality eval(2319KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[He, X.]的文章
[L. Yuan]的文章
[C. Q. Jin and X. H. Zhang]的文章
百度学术
百度学术中相似的文章
[He, X.]的文章
[L. Yuan]的文章
[C. Q. Jin and X. H. Zhang]的文章
必应学术
必应学术中相似的文章
[He, X.]的文章
[L. Yuan]的文章
[C. Q. Jin and X. H. Zhang]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Imaging quality evaluation method of pixel coupled electro-optical imaging system.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。