卷号36期号:6
摘要At present, we typically use large extended radiation source as radiometric calibration device for the out-field work of large aperture dual-waveband infrared theodolite system. This method needs two sets of equipments, which exists the disadvantages of high power consume, inconvenient portable performance and difficult to develop. To solve this problem, the principles, processes and technical performances of different calibration methods are analyzed. Then the Jones method is selected as large aperture infrared theodolite out-field work environment radiometricca libration meth. The dual-band infrared radiometer is developed, which consists of two parts, blackbody lighting tube and reference radiometer. The radiometer uses Newton structure as telescopic system and relay optical path system, and selects InGaAs and PbSe as double-band infrared detectors to calibrate short wave infrared radiation (SWIR) and radiation middle wave infrared (MWIR) respectively. Then the necessity of the reference radiometer calibration to ensure the infrared theodolite final measuring precision is discussed, and different calibration methods and results for calibrating reference radiometer in SWIR and MWIR are presented. Finally, the calibration uncertainty of the radiometer is analyzed, the SWIR and MWIR calibration uncertainties are 4.12% and 2.35% respectively. 2016, Chinese Lasers Press. All right reserved.
文章类型期刊
收录类别EI
语种中文
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/57458
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Zhang, Z.,Z. Wan,J. Sun,et al. Development and calibration of dual-waveband infrared radiometerfor jones calibration method[J]. Guangxue Xuebao/Acta Optica Sinica,2016,36(6).
APA Zhang, Z.,Z. Wan,J. Sun,Z. Liu,&J. Ren and J. Ren.(2016).Development and calibration of dual-waveband infrared radiometerfor jones calibration method.Guangxue Xuebao/Acta Optica Sinica,36(6).
MLA Zhang, Z.,et al."Development and calibration of dual-waveband infrared radiometerfor jones calibration method".Guangxue Xuebao/Acta Optica Sinica 36.6(2016).
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Development and cali(669KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zhang, Z.]的文章
[Z. Wan]的文章
[J. Sun]的文章
百度学术
百度学术中相似的文章
[Zhang, Z.]的文章
[Z. Wan]的文章
[J. Sun]的文章
必应学术
必应学术中相似的文章
[Zhang, Z.]的文章
[Z. Wan]的文章
[J. Sun]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Development and calibration of dual.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。