Changchun Institute of Optics,Fine Mechanics and Physics,CAS
Development and calibration of dual-waveband infrared radiometerfor jones calibration method | |
Zhang, Z.; Z. Wan; J. Sun; Z. Liu; J. Ren and J. Ren | |
2016 | |
发表期刊 | Guangxue Xuebao/Acta Optica Sinica |
卷号 | 36期号:6 |
摘要 | At present, we typically use large extended radiation source as radiometric calibration device for the out-field work of large aperture dual-waveband infrared theodolite system. This method needs two sets of equipments, which exists the disadvantages of high power consume, inconvenient portable performance and difficult to develop. To solve this problem, the principles, processes and technical performances of different calibration methods are analyzed. Then the Jones method is selected as large aperture infrared theodolite out-field work environment radiometricca libration meth. The dual-band infrared radiometer is developed, which consists of two parts, blackbody lighting tube and reference radiometer. The radiometer uses Newton structure as telescopic system and relay optical path system, and selects InGaAs and PbSe as double-band infrared detectors to calibrate short wave infrared radiation (SWIR) and radiation middle wave infrared (MWIR) respectively. Then the necessity of the reference radiometer calibration to ensure the infrared theodolite final measuring precision is discussed, and different calibration methods and results for calibrating reference radiometer in SWIR and MWIR are presented. Finally, the calibration uncertainty of the radiometer is analyzed, the SWIR and MWIR calibration uncertainties are 4.12% and 2.35% respectively. 2016, Chinese Lasers Press. All right reserved. |
文章类型 | 期刊 |
收录类别 | EI |
语种 | 中文 |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/57458 |
专题 | 中科院长春光机所知识产出 |
推荐引用方式 GB/T 7714 | Zhang, Z.,Z. Wan,J. Sun,et al. Development and calibration of dual-waveband infrared radiometerfor jones calibration method[J]. Guangxue Xuebao/Acta Optica Sinica,2016,36(6). |
APA | Zhang, Z.,Z. Wan,J. Sun,Z. Liu,&J. Ren and J. Ren.(2016).Development and calibration of dual-waveband infrared radiometerfor jones calibration method.Guangxue Xuebao/Acta Optica Sinica,36(6). |
MLA | Zhang, Z.,et al."Development and calibration of dual-waveband infrared radiometerfor jones calibration method".Guangxue Xuebao/Acta Optica Sinica 36.6(2016). |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Development and cali(669KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Zhang, Z.]的文章 |
[Z. Wan]的文章 |
[J. Sun]的文章 |
百度学术 |
百度学术中相似的文章 |
[Zhang, Z.]的文章 |
[Z. Wan]的文章 |
[J. Sun]的文章 |
必应学术 |
必应学术中相似的文章 |
[Zhang, Z.]的文章 |
[Z. Wan]的文章 |
[J. Sun]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论