CIOMP OpenIR  > 中科院长春光机所知识产出
Study on the Design of Prism Hyperspectral Imaging System Based on Off-Axis Two-Mirror Littrow Configuration
Yang, J.; J. C. Cui; Bayanheshig; X. D. Qi; Y. G. Tang and X. F. Yao
2016
发表期刊Spectroscopy and Spectral Analysis
卷号36期号:5
摘要To compensate the offset from optimal focal plane position of a space camera due to its complicated launch environment and space operating environment, a new high-precision focusing mechanism was proposed. The mechanism is driven by equal output components, transmitted by a positive and negative slider-crank mechanisms and its guiding is completed by a direct-acting component. The structural composition and motion mechanism were introduced and its error sources and influence factors were analyzed. The focusing mechanism was supported by the direct-acting component with two points and the output force of each point was equivalence, so that it has no synchronization motion error, and characterized by low internal stress in the organization and high swing angle precision. Furthermore, the gap relieving by preload was used in all kinematics pairs to eliminate the error of back lash in the focusing mechanism to improve focusing accuracy. The test parameter was tested in a simulated space environment, and the analysis and experiment results show that the focusing range of the focusing mechanism is 1.7 7 mm, the linear position precision and repeatability are better than 8 m and 2 m respectively, the synchronization motion error is less than 4 m, and the repeatability better than 1. In focusing travel ranges, the tilt angle accuracy of the focusing mirror and its repeatability are better than 5 and 1.5, respectively. These results meet the needs of complex spatial imaging environments. 2016, Science Press. All right reserved.
文章类型期刊
收录类别SCI ; EI
语种中文
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/57344
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Yang, J.,J. C. Cui,Bayanheshig,et al. Study on the Design of Prism Hyperspectral Imaging System Based on Off-Axis Two-Mirror Littrow Configuration[J]. Spectroscopy and Spectral Analysis,2016,36(5).
APA Yang, J.,J. C. Cui,Bayanheshig,X. D. Qi,&Y. G. Tang and X. F. Yao.(2016).Study on the Design of Prism Hyperspectral Imaging System Based on Off-Axis Two-Mirror Littrow Configuration.Spectroscopy and Spectral Analysis,36(5).
MLA Yang, J.,et al."Study on the Design of Prism Hyperspectral Imaging System Based on Off-Axis Two-Mirror Littrow Configuration".Spectroscopy and Spectral Analysis 36.5(2016).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Study on the Design (2636KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Yang, J.]的文章
[J. C. Cui]的文章
[Bayanheshig]的文章
百度学术
百度学术中相似的文章
[Yang, J.]的文章
[J. C. Cui]的文章
[Bayanheshig]的文章
必应学术
必应学术中相似的文章
[Yang, J.]的文章
[J. C. Cui]的文章
[Bayanheshig]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Study on the Design of Prism Hyperspectral Imaging System Based on Off-Axis Two-Mirror Littrow Configuration.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。