CIOMP OpenIR  > 中科院长春光机所知识产出
Calibration method for linear array camera of intersection measurement system
Wu, P.; Y.-J. Wang; H.-H. Sun; Z.-J. Yao and Z.-G. Wu
2016
发表期刊Guangzi Xuebao/Acta Photonica Sinica
卷号45期号:6
摘要In order to improve the spot position detection accuracy for 1550 nm near infrared band. an innovative infinite integral model was proposed. At first, the relationship between InGaAs four-quadrant detector (QD) output signal and the spot real position was deeply analyzed where the laser spot energy displayed a Gaussian profile. By taking into account the error effects of detector diameter and gap size, and introducing the position error compensation factor, an effective spot radius was obtained with a best fit using the least square method, and then a new analytical expression was proposed. Finally, the experiment was made for verifying the performance of our new model in the established InGaAs QD spot detection system. The results of simulation and experiment show that the new model could effectively reduce the spot position detection error for different radii; when the total energy of incident light is about 10 W, the beam radius is 0.75 mm, in the detection range of [-0.75-0.75 mm], the root-mean-square error of 0.003 mm and the maximum position error of 0.009 mm with the new model, are reduced 78.6% and 52.6% than the original model, respectively. Therefore, the new model would have a good prospect in the engineering practice of laser communication or laser radar. 2016, Editorial Board of Journal of Infrared and Laser Engineering. All right reserved.
文章类型期刊
收录类别EI
语种中文
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/57281
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Wu, P.,Y.-J. Wang,H.-H. Sun,et al. Calibration method for linear array camera of intersection measurement system[J]. Guangzi Xuebao/Acta Photonica Sinica,2016,45(6).
APA Wu, P.,Y.-J. Wang,H.-H. Sun,&Z.-J. Yao and Z.-G. Wu.(2016).Calibration method for linear array camera of intersection measurement system.Guangzi Xuebao/Acta Photonica Sinica,45(6).
MLA Wu, P.,et al."Calibration method for linear array camera of intersection measurement system".Guangzi Xuebao/Acta Photonica Sinica 45.6(2016).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Calibration method f(516KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Wu, P.]的文章
[Y.-J. Wang]的文章
[H.-H. Sun]的文章
百度学术
百度学术中相似的文章
[Wu, P.]的文章
[Y.-J. Wang]的文章
[H.-H. Sun]的文章
必应学术
必应学术中相似的文章
[Wu, P.]的文章
[Y.-J. Wang]的文章
[H.-H. Sun]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Calibration method for linear array camera of intersection measurement system.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。