CIOMP OpenIR  > 中科院长春光机所知识产出
Optical system design of multispectral achromatic imaging flow cytometer
Li, C.; B. Guo and Z. Sun
2016
发表期刊Guangxue Xuebao/Acta Optica Sinica
卷号36期号:9
摘要The surface of SiCPwas Ti-coated via melt salt, and the Ti-coated SiCP/Al2014 composites were fabricated by stir casting method. The effect law of size and volume fraction of Ti-coated SiCPon the microstructure and mechanical properties of SiCP/Al2014 composites were investigated. The results show that the Ti-coated processing could effectively improve the distribution uniformity of Ti-coated SiCPin Al matrix. When the size of Ti-coated SiCPkeeps constant, the distribution uniformity of Ti-coated SiCPin Al matrix decreases with increasing volume fraction of SiCP. When volume fraction of SiCPkeeps constant, the distribution uniformity of Ti-coated SiCPin Al matrix increases with increasing size of SiCP. When size of SiCPkeeps constant, the tensile strength of SiCP/Al2014 composites at room temperature increases first then decreases with increasing volume fraction of particles. The SiCP/Al2014 composites with 4% volume fraction of particles possess the highest tensile strength, i.e., composites containing SiCPwith sizes of 5 m and 10 m correspond to tensile strength of 524 MPa and 536 MPa, respectively. The tensile strength of SiCP/Al2014 composites at high temperature (493 K) increases with increasing volume fraction of SiCP. SiCP/Al composites with 6% volume fraction of particles possess the highest tensile strength. The composite with 5 m-SiCPexhibits tensile strength of 308 MPa while that with 10 m-SiCPexhibits tensile strength of 320 MPa when the volume fraction of particles is 6%. 2016, BUAA Culture Media Group Ltd. All right reserved.
文章类型期刊
收录类别EI
语种中文
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/57004
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Li, C.,B. Guo and Z. Sun. Optical system design of multispectral achromatic imaging flow cytometer[J]. Guangxue Xuebao/Acta Optica Sinica,2016,36(9).
APA Li, C.,&B. Guo and Z. Sun.(2016).Optical system design of multispectral achromatic imaging flow cytometer.Guangxue Xuebao/Acta Optica Sinica,36(9).
MLA Li, C.,et al."Optical system design of multispectral achromatic imaging flow cytometer".Guangxue Xuebao/Acta Optica Sinica 36.9(2016).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Optical system desig(1903KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Li, C.]的文章
[B. Guo and Z. Sun]的文章
百度学术
百度学术中相似的文章
[Li, C.]的文章
[B. Guo and Z. Sun]的文章
必应学术
必应学术中相似的文章
[Li, C.]的文章
[B. Guo and Z. Sun]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Optical system design of multispectral achromatic imaging flow cytometer.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。