CIOMP OpenIR  > 中科院长春光机所知识产出
Spectral Calibration of a Solar Spectrometer Based on the Prism-Rotating Method
Gao, Z. Y.; W. Fang; Y. P. Wang and H. Zhang
2016
发表期刊Spectroscopy and Spectral Analysis
卷号36期号:6
摘要The image quality of the traditional Offner spectrometer may be unsatisfied when large dispersion is needed. Furthermore, severe ray obstruction may occur when relative aperture is not small enough. Therefore, an off-plane Offner spectrometer is suggested based on Rowland condition in this paper. An analytical design approach of an imaging spectrometer based on off-plane Offner configuration is presented. Astigmatism and coma are corrected in the design without ray obstruction. An imaging spectrometer is designed using the configuration with a spectral range from 350 nm to 1000 nm. The size of the spectral image is 12.6 mm. The modulation transfer functions in total fields of view and the whole spectral range are more than 0.78. The root mean square (RMS) spot radiuses are smaller than 4 m. Meanwhile, the smile and keystone of the system are both better than 1% of a pixel size. Finally, a contrast between the off-plane Offner spectrometer and the in-plane configuration is performed. The result demonstrates that the off-plane Offner spectrometer has a better image quality for high spectral resolution if a shot entrance slit is allowed. There is also an advantage in eliminating the smile and keystone. The configuration can be applied to imaging spectrometers with small dimension and high spectral resolution. 2016, Chinese Laser Press. All right reserved.
文章类型期刊
收录类别SCI ; EI
语种中文
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/56925
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Gao, Z. Y.,W. Fang,Y. P. Wang and H. Zhang. Spectral Calibration of a Solar Spectrometer Based on the Prism-Rotating Method[J]. Spectroscopy and Spectral Analysis,2016,36(6).
APA Gao, Z. Y.,W. Fang,&Y. P. Wang and H. Zhang.(2016).Spectral Calibration of a Solar Spectrometer Based on the Prism-Rotating Method.Spectroscopy and Spectral Analysis,36(6).
MLA Gao, Z. Y.,et al."Spectral Calibration of a Solar Spectrometer Based on the Prism-Rotating Method".Spectroscopy and Spectral Analysis 36.6(2016).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Gao, Z. Y.]的文章
[W. Fang]的文章
[Y. P. Wang and H. Zhang]的文章
百度学术
百度学术中相似的文章
[Gao, Z. Y.]的文章
[W. Fang]的文章
[Y. P. Wang and H. Zhang]的文章
必应学术
必应学术中相似的文章
[Gao, Z. Y.]的文章
[W. Fang]的文章
[Y. P. Wang and H. Zhang]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。