CIOMP OpenIR  > 中科院长春光机所知识产出
Analysis of misalignment sensitivity of generalized ring resonator for the trace gas concentration detection instrument based on CRDS
Cui, L. and C. Yan
2016
发表期刊Chemical Engineering Transactions
卷号55
摘要An automatic algorithm to rapidly process the spectrogram of the echelle grating spectrometer was proposed based on the linear fitting method of centroid extraction, solving the problem that the echelle grating spectrometer can not calibrate wavelength of incident rays through the two-dimensional spectrogram which was formed by cross dispersion. The background correction method is adopted to process the spectrogram based on the distribution characteristics of background light of the spectrogram of echelle grating spectrometer, thereby the calculation efficiency of the optical spot extraction algorithm of the follow-up spectrogram of echelle grating spectrometer was improved. The curve fitting center positioning algorithm based on centroid was employed to improve the extraction precision of the optical spot position to the sub-pixel magnitude. The auto-match model of the theoretical spectrogram of echelle grating spectrometer and the actual two-dimensional spectrogram were established and the method of interpolation was adopted to calculate the wavelength at the coordinate position, which is not listed in the recovery model of the spectrogram based on the linear dispersion characteristics of optical grating. The result shows that: the processing time of the whole spectrogram by this algorithm does not exceed 3 s and the wavelength extraction precision is up to 10-2nm, not only achieving the automatic wavelength extraction of the echelle grating spectrometer but also improving the wavelength extraction precision. 2016, Science Press. All right reserved.
文章类型期刊
收录类别SCI ; EI
语种英语
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/56893
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Cui, L. and C. Yan. Analysis of misalignment sensitivity of generalized ring resonator for the trace gas concentration detection instrument based on CRDS[J]. Chemical Engineering Transactions,2016,55.
APA Cui, L. and C. Yan.(2016).Analysis of misalignment sensitivity of generalized ring resonator for the trace gas concentration detection instrument based on CRDS.Chemical Engineering Transactions,55.
MLA Cui, L. and C. Yan."Analysis of misalignment sensitivity of generalized ring resonator for the trace gas concentration detection instrument based on CRDS".Chemical Engineering Transactions 55(2016).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Cui, L. and C. Yan]的文章
百度学术
百度学术中相似的文章
[Cui, L. and C. Yan]的文章
必应学术
必应学术中相似的文章
[Cui, L. and C. Yan]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。