CIOMP OpenIR  > 中科院长春光机所知识产出
Encoded error calibration for a coded aperture spectrometer based on deconvolution
Chi, M. B.; Y. H. Wu; D. D. Ge; W. C. Zhou; P. Hao and Y. S. Liu
2016
发表期刊Applied Optics
卷号55期号:6
摘要A new strategy to synthesize hierarchical, porous titania/carbon (TiO2/C) hybrid microspheres via solvothermal reaction in N,N'-dimethyl formamide (DMF) has been developed. In situ formed polystyrene (PS) colloids have been used as templating agent and carbon source, through which TiO2/PS microspheres with a diameter of ca. 1 mu m are built by packed TiO2 nanoparticles of tens of nanometers. The TiO2/PS microspheres are converted to TiO2/C microspheres with different amounts of carbon under controlled calcination condition. The mechanism investigation unveils that the introduction of concentrated HCl creates surface tension between PS and DMF, leading to the formation of PS colloids in solution. The solvothermal treatment further promotes the formation of PS colloids and integration of the titania nanoparticles within the PS colloids. The morphology, crystallinity, nature and content of carbon, UV-Vis absorption, carbon doping, pore size distribution, pore volume, and BET surface area of the TiO2 micro spheres with different amounts of carbon have been measured. The applications of the TiO2/C hybrid microspheres as photo catalyst for water splitting and lithium-ion battery anode have been demonstrated. Superior photo catalytic activity for hydrogen conversion under both full spectrum and visible light illumination compared to commercial P25 has been observed for the TiO2/C microspheres with 2 wt% of carbon. Besides, the TiO2/C microspheres with 8 wt% of carbon as lithium-ion battery anode showed a much higher capacity than the bare TiO2 microsphere anode. The origin for the enhanced performance as photo catalyst and lithium-ion battery anode is discussed. (C) 2016 Elsevier Inc. All rights reserved.
文章类型期刊
收录类别SCI ; EI
语种英语
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/56887
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Chi, M. B.,Y. H. Wu,D. D. Ge,et al. Encoded error calibration for a coded aperture spectrometer based on deconvolution[J]. Applied Optics,2016,55(6).
APA Chi, M. B.,Y. H. Wu,D. D. Ge,W. C. Zhou,&P. Hao and Y. S. Liu.(2016).Encoded error calibration for a coded aperture spectrometer based on deconvolution.Applied Optics,55(6).
MLA Chi, M. B.,et al."Encoded error calibration for a coded aperture spectrometer based on deconvolution".Applied Optics 55.6(2016).
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Encoded error calibr(842KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Chi, M. B.]的文章
[Y. H. Wu]的文章
[D. D. Ge]的文章
百度学术
百度学术中相似的文章
[Chi, M. B.]的文章
[Y. H. Wu]的文章
[D. D. Ge]的文章
必应学术
必应学术中相似的文章
[Chi, M. B.]的文章
[Y. H. Wu]的文章
[D. D. Ge]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Encoded error calibration for a coded aperture spectrometer based on deconvolution.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。