CIOMP OpenIR  > 中科院长春光机所知识产出
High-resolution imaging by Bi-linear CCD shifting sampling
Xu, S.; C. Chen; B. Sun; X. Zhang and J. Ren
2015
发表期刊Zhongguo Jiguang/Chinese Journal of Lasers
卷号42期号:9
摘要The resolution of remote sensing camera is restricted by the charge coupled device (CCD) pixel size. To solve the problem, imaging capability of optical system in frequency bandwidth exceeding Nyquist frequency is used to develop a camera which consists of two linear CCDs. These two CCDs are stitched together with a halfpixel width displacement in both directions along and perpendicular to the CCD axis. The principle of improving the resolution of the proposed system is presented. In hipermode, one way interpolation algorithm based on integrated gradients to determine the direction of interpolation is proposed to avoid zipper effect caused by average method. In supermode, high resolution image is acquired in real time by using random access memory (RAM) blocks inside field programmable gate array (FPGA) to regroup image stagger. Gray mean gradients (GMG) of the two high resolution images are increased by factors of 62.5% and 78.3% respectively after using Wiener filter. Results show that the proposed algorithm can make image edge clear and intact. The effect of the algorithm is better than average method and the hardware implementation is easy. The resolution is 1.16 and 1.6 times greater than that of conventional system. Two imaging method can also reduce the image frequency aliasing. Sampling phase staggered technology can take advantage of imaging capability of optical system in high-frequency bandwidth and perform high-resolution imaging. , 2015, Science Press. All right reserved.
文章类型期刊论文
收录类别EI
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/56389
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Xu, S.,C. Chen,B. Sun,et al. High-resolution imaging by Bi-linear CCD shifting sampling[J]. Zhongguo Jiguang/Chinese Journal of Lasers,2015,42(9).
APA Xu, S.,C. Chen,B. Sun,&X. Zhang and J. Ren.(2015).High-resolution imaging by Bi-linear CCD shifting sampling.Zhongguo Jiguang/Chinese Journal of Lasers,42(9).
MLA Xu, S.,et al."High-resolution imaging by Bi-linear CCD shifting sampling".Zhongguo Jiguang/Chinese Journal of Lasers 42.9(2015).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
双线阵CCD错位采样高分辨成像_徐少雄.(1611KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Xu, S.]的文章
[C. Chen]的文章
[B. Sun]的文章
百度学术
百度学术中相似的文章
[Xu, S.]的文章
[C. Chen]的文章
[B. Sun]的文章
必应学术
必应学术中相似的文章
[Xu, S.]的文章
[C. Chen]的文章
[B. Sun]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 双线阵CCD错位采样高分辨成像_徐少雄.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。