Changchun Institute of Optics,Fine Mechanics and Physics,CAS
Calibration for wide field of view infrared theodolite | |
Liu, Y.; H. Yan and D. Wang | |
2015 | |
发表期刊 | Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering |
卷号 | 44期号:3页码:832-836 |
摘要 | In order to improve the precision of wide field of view infrared optoelectronic theodolite, a calibration method based on multiple regression analysis was established, the reasons which effected the precision of wide field of view infrared optoelectronic theodolite were analyzed and the solution was proposed. First, the measurement theory and shipment of wide field of view infrared optoelectronic theodolit were introduced, the relationship between the object and the image in geodetic coordinates was analyzed. Then, the reason which effected the measurement of wide field of view infrared optoelectronic theodolite was the error between optical design, produce and machining, and the effect must be resolved after installation and adjustment. Lastly, a method based on multiple regression analysis was proposed, the calibration mode was established in all field of view by multiple regression analysis, after that, when measurement, the measurement data will be revised by the calibration multiple regression analysis mode. Experimental results indicate that the precision of the system in horizontal and vertical are improved from 21.44 and 26.81 to 7.62 and 6.38. This method improves the measurement precision effectively. , 2015, Chinese Society of Astronautics. All right reserved. |
文章类型 | 期刊论文 |
收录类别 | EI |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/56284 |
专题 | 中科院长春光机所知识产出 |
推荐引用方式 GB/T 7714 | Liu, Y.,H. Yan and D. Wang. Calibration for wide field of view infrared theodolite[J]. Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering,2015,44(3):832-836. |
APA | Liu, Y.,&H. Yan and D. Wang.(2015).Calibration for wide field of view infrared theodolite.Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering,44(3),832-836. |
MLA | Liu, Y.,et al."Calibration for wide field of view infrared theodolite".Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering 44.3(2015):832-836. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
大视场红外光电经纬仪精度标定.caj(266KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Liu, Y.]的文章 |
[H. Yan and D. Wang]的文章 |
百度学术 |
百度学术中相似的文章 |
[Liu, Y.]的文章 |
[H. Yan and D. Wang]的文章 |
必应学术 |
必应学术中相似的文章 |
[Liu, Y.]的文章 |
[H. Yan and D. Wang]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论