Changchun Institute of Optics,Fine Mechanics and Physics,CAS
Kinematic coupling design and analysis for 30 m telescope tertiary mirror system | |
Zhao, H.; J. Zhang; F. Yang and P. Guo | |
2015 | |
发表期刊 | Guangxue Xuebao/Acta Optica Sinica |
卷号 | 35期号:3 |
摘要 | In order to avoid the introduction of aberrations which make the image quality degrade, both alignment and shift of the optical components are strictly guaranteed in the optical system. The kinematic interface has a wonderful performance in repeatability and low level of contact stress. So it is widely used in optical system. The thirty meter telescope (TMT) is an Ritchey-Chirtien (R-C) optical system. The tertiary mirror is employed to bend the light to the instruments. According to the requirement of the accuracy assembly this mirror is frequently removed to clean and recoat. So a kinematic interface is designed to meet the requirement. The study on the kinematic principle in positioning the rigid body is introduced. Then a preliminary design is constructed according with the mechanical principles. Thus the Hertz contact theory and IBM wear theory are employed to check the contact stress and the wear situation. At last, a positioning accuracy simulation is carried out by the Monte-Carlo method. In addition, a simulation is carried out to analyze the support performance in Ansys software. And some parameters is optimized. The results show that both the contact stress and the wear situation can meet the requirements. In addition, the repeatability in three directions and the support performance are achieved. , 2015, Chinese Optical Society. All right reserved. |
文章类型 | 期刊论文 |
收录类别 | EI |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/56224 |
专题 | 中科院长春光机所知识产出 |
推荐引用方式 GB/T 7714 | Zhao, H.,J. Zhang,F. Yang and P. Guo. Kinematic coupling design and analysis for 30 m telescope tertiary mirror system[J]. Guangxue Xuebao/Acta Optica Sinica,2015,35(3). |
APA | Zhao, H.,J. Zhang,&F. Yang and P. Guo.(2015).Kinematic coupling design and analysis for 30 m telescope tertiary mirror system.Guangxue Xuebao/Acta Optica Sinica,35(3). |
MLA | Zhao, H.,et al."Kinematic coupling design and analysis for 30 m telescope tertiary mirror system".Guangxue Xuebao/Acta Optica Sinica 35.3(2015). |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
30m望远镜三镜系统运动学接口设计及分析(1417KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |