摘要In order to avoid the introduction of aberrations which make the image quality degrade, both alignment and shift of the optical components are strictly guaranteed in the optical system. The kinematic interface has a wonderful performance in repeatability and low level of contact stress. So it is widely used in optical system. The thirty meter telescope (TMT) is an Ritchey-Chirtien (R-C) optical system. The tertiary mirror is employed to bend the light to the instruments. According to the requirement of the accuracy assembly this mirror is frequently removed to clean and recoat. So a kinematic interface is designed to meet the requirement. The study on the kinematic principle in positioning the rigid body is introduced. Then a preliminary design is constructed according with the mechanical principles. Thus the Hertz contact theory and IBM wear theory are employed to check the contact stress and the wear situation. At last, a positioning accuracy simulation is carried out by the Monte-Carlo method. In addition, a simulation is carried out to analyze the support performance in Ansys software. And some parameters is optimized. The results show that both the contact stress and the wear situation can meet the requirements. In addition, the repeatability in three directions and the support performance are achieved. , 2015, Chinese Optical Society. All right reserved.
文章类型期刊论文
收录类别EI
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/56224
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Zhao, H.,J. Zhang,F. Yang and P. Guo. Kinematic coupling design and analysis for 30 m telescope tertiary mirror system[J]. Guangxue Xuebao/Acta Optica Sinica,2015,35(3).
APA Zhao, H.,J. Zhang,&F. Yang and P. Guo.(2015).Kinematic coupling design and analysis for 30 m telescope tertiary mirror system.Guangxue Xuebao/Acta Optica Sinica,35(3).
MLA Zhao, H.,et al."Kinematic coupling design and analysis for 30 m telescope tertiary mirror system".Guangxue Xuebao/Acta Optica Sinica 35.3(2015).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
30m望远镜三镜系统运动学接口设计及分析(1417KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zhao, H.]的文章
[J. Zhang]的文章
[F. Yang and P. Guo]的文章
百度学术
百度学术中相似的文章
[Zhao, H.]的文章
[J. Zhang]的文章
[F. Yang and P. Guo]的文章
必应学术
必应学术中相似的文章
[Zhao, H.]的文章
[J. Zhang]的文章
[F. Yang and P. Guo]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 30m望远镜三镜系统运动学接口设计及分析.caj
格式: caj
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。