摘要The Total Solar Irradiance (TSI) cavity in an Absolute Radiance Calibration Primary Radiometer(ARCPR) for space remote sensing should have an absorptance more than 0.9999 and the measurement uncertainty superior to 0.001%. Therefore, a cylindrical sloping bottom cavity was used as a receiver cavity for calibration of the TSI because of its superior performance in the space and cryogenic environments. Then, the absorptance of the cylindrical sloping bottom cavity was measured. The characteristics of the cylindrical sloping bottom cavity were introduced, and why the cavity was used as the receiver cavity in cryogenic radiometer was analyzed. Furthermore, the principle of the absorptance measured by a substitution method was expounded. A reference light path was added to monitor the stability of a laser to improve the measurement repeatability and accuracy. Finally, the absorptance of sloping bottom cavity was measured using this method, and the uncertainty of measurement results was analyzed. Experimental results indicate that the absorptance of sloping bottom cavity is 0.999 9280.000 005, superior to that of the calibration standard of the blackbody cavity, which verifies it is feasibility to use the sloping bottom cavity as the TSI cavity for measuring the TSI. The experiments also verify that the ratio of single voltage and reference voltage could be used to calculate the cavity absorptance, and could improve the uncertainty of measurement result. This method is fit for measuring the absorptance of an ultra high absorptance cavity. 2015, SCIENCE PRESS. All right reserved.
文章类型期刊论文
收录类别EI
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/56127
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Yi, X.-L.,Z.-L. Yang,X. Ye,et al. Absorptance measurement for sloping bottom cavity of cryogenic radiometer[J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering,2015,23(10):2733-2739.
APA Yi, X.-L.,Z.-L. Yang,X. Ye,K. Wang,&W. Fang and Y.-P. Wang.(2015).Absorptance measurement for sloping bottom cavity of cryogenic radiometer.Guangxue Jingmi Gongcheng/Optics and Precision Engineering,23(10),2733-2739.
MLA Yi, X.-L.,et al."Absorptance measurement for sloping bottom cavity of cryogenic radiometer".Guangxue Jingmi Gongcheng/Optics and Precision Engineering 23.10(2015):2733-2739.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
低温辐射计斜底腔吸收比测量.caj(251KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Yi, X.-L.]的文章
[Z.-L. Yang]的文章
[X. Ye]的文章
百度学术
百度学术中相似的文章
[Yi, X.-L.]的文章
[Z.-L. Yang]的文章
[X. Ye]的文章
必应学术
必应学术中相似的文章
[Yi, X.-L.]的文章
[Z.-L. Yang]的文章
[X. Ye]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 低温辐射计斜底腔吸收比测量.caj
格式: caj
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。