Changchun Institute of Optics,Fine Mechanics and Physics,CAS
Suppression of metal artifact in computed tomography by reweighted total variation reconstruction | |
Li, M.![]() | |
2015 | |
发表期刊 | Guangxue Jingmi Gongcheng/Optics and Precision Engineering
![]() |
卷号 | 23期号:6页码:1714-1721 |
摘要 | A novel metal artifact reduction algorithm based on a Reweighted Total Variation (RWTV) reconstruction was proposed to suppress the metal artifacts in Computed Tomography (CT) images to improve the image quality. A user-defined weight function was used as penalty weight to generate the weighted Total Variation (TV) model. The reweighted TV reconstruction algorithm was implemented through solving alternately the weighted TV minimization problem and updating the weight procedure. Then, the algorithm was used in the reconstruction experiments for projections from forward projecting phantom and clinical data respectively. The digital phantom experiments show that the proposed algorithm has the topmost spatial resolution of reconstructed images in 60 sampling angles. Furthermore, the signal-to-noise ratios of images through the proposed algorithm are 17.5236, 7.1452 dB higher than those of images reconstructed by Smooth Interpolation Metal Artifact Reduction (SI-MAR) algorithm and TV minimization based on Constrained Optimization-Penalized Smoothness (CO-PS) algorithm respectively. Clinical experimental results demonstrate that the proposed algorithm successfully suppresses the metal artifacts and clearly restores the anatomical structure in the skull. Moreover, the quality of reconstructed images has been greatly improved by the proposed metal artifact suppression algorithm. , 2015, Chinese Academy of Sciences. All right reserved. |
文章类型 | 期刊论文 |
收录类别 | EI |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/56053 |
专题 | 中科院长春光机所知识产出 |
推荐引用方式 GB/T 7714 | Li, M.,J. Zheng,C. Zhang,et al. Suppression of metal artifact in computed tomography by reweighted total variation reconstruction[J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering,2015,23(6):1714-1721. |
APA | Li, M.,J. Zheng,C. Zhang,&Z. Zhou and T. Zhang.(2015).Suppression of metal artifact in computed tomography by reweighted total variation reconstruction.Guangxue Jingmi Gongcheng/Optics and Precision Engineering,23(6),1714-1721. |
MLA | Li, M.,et al."Suppression of metal artifact in computed tomography by reweighted total variation reconstruction".Guangxue Jingmi Gongcheng/Optics and Precision Engineering 23.6(2015):1714-1721. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
应用变权全变分重建抑制CT金属伪影.ca(398KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论