摘要A measurement method for the lens centering error based on double phase-encoding optical Joint Transform Correlator(JTC) was proposed for improving the measuring accuracy and determining the orientation of the centering error. On the basis of the principle of traditional JTC, two phase functions were utilized to code the reference image and the joint power spectrum, and proper filters were chosen to eliminate the effect of the sidelobe and to obtain an output with one cross-correlation peak. Then, this JTC technique after double phase-encoding was used to detect the displacement vectors between target images and reference image and to fit a circle using the displacement vectors. The vector between the center of the fitting circle and a certain point on the fitting circle is the magnified centering vector of corresponding angle, which means that the size and orientation of the centering error have been determined simultaneously. The experimental results show that the outputs keep only one speculate cross-correlation peak after double phase-encoding, which implements the displacement measurement with sub-pixel accuracy. This technology is used to measure the centering error of a lens accurately, the experimental standard deviation is 0.1 m, and the biggest absolute error is 0.3 m, which meets the requirement of centering error measurement. 2015, SCIENCE PRESS. All right reserved.
文章类型期刊论文
收录类别EI
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/56046
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Li, C.-C. and Y. Gong. Measurement of lens centering error based on joint transform correlator[J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering,2015,23(10):2785-2793.
APA Li, C.-C. and Y. Gong.(2015).Measurement of lens centering error based on joint transform correlator.Guangxue Jingmi Gongcheng/Optics and Precision Engineering,23(10),2785-2793.
MLA Li, C.-C. and Y. Gong."Measurement of lens centering error based on joint transform correlator".Guangxue Jingmi Gongcheng/Optics and Precision Engineering 23.10(2015):2785-2793.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
采用联合变换相关的透镜中心偏差测量.ca(430KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Li, C.-C. and Y. Gong]的文章
百度学术
百度学术中相似的文章
[Li, C.-C. and Y. Gong]的文章
必应学术
必应学术中相似的文章
[Li, C.-C. and Y. Gong]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 采用联合变换相关的透镜中心偏差测量.caj
格式: caj
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。