CIOMP OpenIR  > 中科院长春光机所知识产出
Mechanical design and performance evaluation for plane grating monochromator in a soft X-ray microscopy beamline at SSRF
Gong, X. P. and Q. P. Lu
2015
发表期刊Journal of X-Ray Science and Technology
卷号23期号:4页码:409-421
摘要A new monochromator is designed to develop a high performance soft X-ray microscopy beamline at Shanghai Synchrotron Radiation Facility (SSRF). But owing to its high resolving power and high accurate spectrum output, there exist many technical difficulties. In the paper presented, as two primary design targets for the monochromator, theoretical energy resolution and photon flux of the beamline are calculated. For wavelength scanning mechanism, primary factors affecting the rotary angle errors are presented, and the measuring results are 0.15 '' and 0.17 '' for plane mirror and plane grating, which means that it is possible to provide sufficient scanning precision to specific wavelength. For plane grating switching mechanism, the repeatabilities of roll, yaw and pitch angles are 0.08 '', 0.12 '' and 0.05 '', which can guarantee the high accurate switch of the plane grating effectively. After debugging, the repeatability of light spot drift reaches to 0.7 '', which further improves the performance of the monochromator. The commissioning results show that the energy resolving power is higher than 10000 at Ar L-edge, the photon flux is higher than 1 x 10(8) photons/sec/200 mA, and the spatial resolution is better than 30 nm, demonstrating that the monochromator performs very well and reaches theoretical predictions.
收录类别SCI ; EI
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/55253
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Gong, X. P. and Q. P. Lu. Mechanical design and performance evaluation for plane grating monochromator in a soft X-ray microscopy beamline at SSRF[J]. Journal of X-Ray Science and Technology,2015,23(4):409-421.
APA Gong, X. P. and Q. P. Lu.(2015).Mechanical design and performance evaluation for plane grating monochromator in a soft X-ray microscopy beamline at SSRF.Journal of X-Ray Science and Technology,23(4),409-421.
MLA Gong, X. P. and Q. P. Lu."Mechanical design and performance evaluation for plane grating monochromator in a soft X-ray microscopy beamline at SSRF".Journal of X-Ray Science and Technology 23.4(2015):409-421.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Gong-2015-Mechanical(4735KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Gong, X. P. and Q. P. Lu]的文章
百度学术
百度学术中相似的文章
[Gong, X. P. and Q. P. Lu]的文章
必应学术
必应学术中相似的文章
[Gong, X. P. and Q. P. Lu]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Gong-2015-Mechanical design an.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。