Changchun Institute of Optics,Fine Mechanics and Physics,CAS
Fabrication and analysis of tall-stepped mirror for use in static Fourier transform infrared spectrometer | |
Chen, C.; J. Q. Liang; Z. Z. Liang; J. U. Lu; Y. X. Qin; C. Tian and W. B. Wang | |
2015 | |
发表期刊 | Optics and Laser Technology
![]() |
卷号 | 75页码:42533 |
摘要 | A method of "slope splicing" is proposed to build a tall-stepped mirror with high precision in a stepped-mirror-based static Fourier transform infrared spectrometer. The structural parameters were designed, and their errors were analyzed. We present the test results and an analysis of the combined effect of the errors on the recovered spectrum. The spectrum-constructing error of the constructed spectrum, 5.81%, meets the requirements for the system and suitable for realization of a miniaturized spectrometer. We performed experiments with the tall-stepped mirror to obtain the interferogram and spectrum of a silicon carbide light source. Further work is needed to optimize the capability of the system. (C) 2015 Elsevier Ltd. All rights reserved. |
收录类别 | SCI ; EI |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/55197 |
专题 | 中科院长春光机所知识产出 |
推荐引用方式 GB/T 7714 | Chen, C.,J. Q. Liang,Z. Z. Liang,et al. Fabrication and analysis of tall-stepped mirror for use in static Fourier transform infrared spectrometer[J]. Optics and Laser Technology,2015,75:42533. |
APA | Chen, C.,J. Q. Liang,Z. Z. Liang,J. U. Lu,Y. X. Qin,&C. Tian and W. B. Wang.(2015).Fabrication and analysis of tall-stepped mirror for use in static Fourier transform infrared spectrometer.Optics and Laser Technology,75,42533. |
MLA | Chen, C.,et al."Fabrication and analysis of tall-stepped mirror for use in static Fourier transform infrared spectrometer".Optics and Laser Technology 75(2015):42533. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Chen-2015-Fabricatio(2910KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论