CIOMP OpenIR  > 中科院长春光机所知识产出
The Effect of MSC Spectral Pretreatment Regions on Near Infrared Spectroscopy Calibration Results
Wang D. M.; Ji J. M.; Gao H. Z.
2014
发表期刊Spectroscopy and Spectral Analysis
ISSNISBN/1000-0593
卷号34期号:9页码:2387-2390
摘要In the present paper, 60 whole wheat flour samples were prepared and corresponding NIR spectra were collected. After the determinations of calibration range, several spectral sub-regions containing calibration range and prepared for the correction using multiple scattering correction (MSC) were obtained in the whole spectral region firstly, and MSC correction based on different spectral sub-region followed subsequently. Corresponding spectral data were obtained from the fixed calibration range of the spectra corrected based on different regions. Several partial least squares regression (PLSR) calibration models for analyzing protein content of whole wheat flour were established based on corresponding spectral data, and according to the performance about the calibration coefficient and the root mean square error of cross validation (RMSEV) of every calibration, the effects of MSC pretreatment spectral region on PLSR calibration results were investigated and the pretreatment spectral regions were optimized by comparing the performance of more calibration models. For the optimized calibration, the calibration coefficient and the RMSECV improved compared with the calibration established based on the spectral data corrected using MSC in the fixed region of calibration. The correlation coefficient can be raised from 0. 96 to 0. 98 and RMSECV can be decreased from 0 .37% to 0. 32%. The results show that the capability of MSC on correcting the spectral interference information of non-chemical absorption can be influenced by preprocessing spectral regions, the performance of calibration model can be improved by optimizing the MSC pretreatment spectral region, and the appropriate pretreatment spectral region is prerequisite to obtain the best calibration results while using MSC for near-infrared spectra analysis.
收录类别SCI ; EI
语种中文
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/44448
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Wang D. M.,Ji J. M.,Gao H. Z.. The Effect of MSC Spectral Pretreatment Regions on Near Infrared Spectroscopy Calibration Results[J]. Spectroscopy and Spectral Analysis,2014,34(9):2387-2390.
APA Wang D. M.,Ji J. M.,&Gao H. Z..(2014).The Effect of MSC Spectral Pretreatment Regions on Near Infrared Spectroscopy Calibration Results.Spectroscopy and Spectral Analysis,34(9),2387-2390.
MLA Wang D. M.,et al."The Effect of MSC Spectral Pretreatment Regions on Near Infrared Spectroscopy Calibration Results".Spectroscopy and Spectral Analysis 34.9(2014):2387-2390.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
多元散射校正预处理波段对近红外光谱定标模(135KB) 开放获取CC BY-ND浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Wang D. M.]的文章
[Ji J. M.]的文章
[Gao H. Z.]的文章
百度学术
百度学术中相似的文章
[Wang D. M.]的文章
[Ji J. M.]的文章
[Gao H. Z.]的文章
必应学术
必应学术中相似的文章
[Wang D. M.]的文章
[Ji J. M.]的文章
[Gao H. Z.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 多元散射校正预处理波段对近红外光谱定标模型的影响_王动民.caj
格式: caj
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。