CIOMP OpenIR  > 中科院长春光机所知识产出
Temporal properties study of ocular wave aberrations with high frequency sampling
Zheng X.; Liu R.; Xia M.; Li D.; Xuan L.
2014
发表期刊Guangxue Xuebao/Acta Optica Sinica
ISSNISBN/02532239
卷号34期号:7
摘要Temporal properties of ocular wave aberrations are researched to improve the performance of eye aberration correction based on adaptive optical systems and the result for retinal imaging. Using a Shack-Hartmann wavefront sensor at a sampling rate of 330 Hz and exposure time of 3 ms, an optical system is constructed to detect human eye's wave aberration. The averaged root mean square (RMS) of detecting errors of the system is proved to be 0.01 by error analysis and an experiment on schematic eye. Detection results show that the existence of fluctuations of ocular wave aberration above 150 Hz can probably impact the performance of adaptive optics systems for wave aberration correction. These fluctuations can be reduced by increasing the detection and exposure times of the detector. In order to reach the diffraction limit, for eyes in the state of steady gaze, correction residual error RMS of adaptive optical system is less than /14, when detecting exposure time is 3 ms and detecting correction period is less than 45 ms. while the detecting correction period can increase to 62 ms as long as the exposure time is set to 6 ms. Analysis on tilt aberration proves that exposure time of high resolution retinal imaging should be less than 9 ms to avoid horizontal movements. Weighting the tradeoff between aberration fluctuation and horizontal movements, exposure times of detection and imaging are both set to about 6 ms.
收录类别EI
语种中文
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/44443
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Zheng X.,Liu R.,Xia M.,et al. Temporal properties study of ocular wave aberrations with high frequency sampling[J]. Guangxue Xuebao/Acta Optica Sinica,2014,34(7).
APA Zheng X.,Liu R.,Xia M.,Li D.,&Xuan L..(2014).Temporal properties study of ocular wave aberrations with high frequency sampling.Guangxue Xuebao/Acta Optica Sinica,34(7).
MLA Zheng X.,et al."Temporal properties study of ocular wave aberrations with high frequency sampling".Guangxue Xuebao/Acta Optica Sinica 34.7(2014).
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
高频采样下人眼波像差特性研究_郑贤良.c(362KB) 开放获取CC BY-ND浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zheng X.]的文章
[Liu R.]的文章
[Xia M.]的文章
百度学术
百度学术中相似的文章
[Zheng X.]的文章
[Liu R.]的文章
[Xia M.]的文章
必应学术
必应学术中相似的文章
[Zheng X.]的文章
[Liu R.]的文章
[Xia M.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 高频采样下人眼波像差特性研究_郑贤良.caj
格式: caj
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。