Study on the Best Detector-Distance of Noninvasive Biochemical Examination by Monte Carlo Simulation
Dong Y. F.; Lu Q. P.; Ding H. Q.; Gao H. Z.
2014
发表期刊Spectroscopy and Spectral Analysis
ISSNISBN/1000-0593
卷号34期号:4页码:942-946
摘要The present paper studies the best detector-distance to improve the near-infrared spectrum signal intensity of the dermis layer and eliminate the interference of the epidermis and subcutaneous layer. First, we analyzed the organizational structure of the skin and calculated the tissue optical parameters of different layers. And we established the Monte Carlo model with the example of glucose absorption peak at 2 270 nm. Then, we used the Monte Carlo method to simulate the light transmission rules in the skin, obtaining the average path length, the average visit depth and the fractions of absorbed energy at each layer with the change in critical angle and detector-distance. The results show that when the photons are incident at an angle less than 45 degrees, you can ignore the effect of the incident angle on photon transmission path, and when the detector-distance is 1 mm, the fraction of absorbed photon energy by the dermis layer is the largest, while it can ensure more energy received by detector. We determined that the best detector-distance is 1mm, which successfully avoids the interference of the epidermis spectral information and obtains large amounts of blood in the dermis layer, which is conducive to the near-infrared non-invasive measurement of biochemical components and the subsequent experiments.
收录类别SCI ; EI
语种中文
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/44409
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Dong Y. F.,Lu Q. P.,Ding H. Q.,et al. Study on the Best Detector-Distance of Noninvasive Biochemical Examination by Monte Carlo Simulation[J]. Spectroscopy and Spectral Analysis,2014,34(4):942-946.
APA Dong Y. F.,Lu Q. P.,Ding H. Q.,&Gao H. Z..(2014).Study on the Best Detector-Distance of Noninvasive Biochemical Examination by Monte Carlo Simulation.Spectroscopy and Spectral Analysis,34(4),942-946.
MLA Dong Y. F.,et al."Study on the Best Detector-Distance of Noninvasive Biochemical Examination by Monte Carlo Simulation".Spectroscopy and Spectral Analysis 34.4(2014):942-946.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
基于蒙特卡罗模拟的无创生化检测最佳探测距(1290KB) 开放获取CC BY-ND浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Dong Y. F.]的文章
[Lu Q. P.]的文章
[Ding H. Q.]的文章
百度学术
百度学术中相似的文章
[Dong Y. F.]的文章
[Lu Q. P.]的文章
[Ding H. Q.]的文章
必应学术
必应学术中相似的文章
[Dong Y. F.]的文章
[Lu Q. P.]的文章
[Ding H. Q.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 基于蒙特卡罗模拟的无创生化检测最佳探测距离的研究_董艳飞.caj
格式: caj
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。