CIOMP OpenIR  > 中科院长春光机所知识产出
Static and dynamic contrast calibration of target source for target acquisition capability detecting equipment
Huang X.; Shen X.; Ye L.; Zhao Y.; Wang S.
2014
发表期刊Guangxue Xuebao/Acta Optica Sinica
ISSNISBN/02532239
卷号34期号:11
摘要In order to realize the static and dynamic contrast calibration of the adjustable contrast optical target device for measuring the low-contrast target capture capability of photoelectric tracker, a target sources contrast measurement system is established for researching the relationship between image contrast and optical contrast. The static target sources image contrast is analyzed and the static calibration curve based on the least squares method is obtained. The military standard rules and the static calibration method, according to the dynamic target sources unique deformation effect and gray gradual change effect, which leads to the problem of lacking uniform and accurate target gray extraction method; discriminant analysis based on mathematical statistical methods is used to classify target gray extraction frame dimensions by different gray values. Then, the scatterplots are applied to visualize the relationship between the extraction frame size and gray distribution, which makes the extraction frame size clear and exclude harmful effects from the above two effects on calibration. Dynamic contrast calibration curves are mapped out under different rates conditions. Experimental results indicate that the accuracy of extraction frame selected is more than 94% and the evaluation parameters of the static and dynamic calibration fitting equations: R2 and Radj2 are both better than 99%, calibration precision S is better than 0.006, which demonstrates that the method is feasible and can satisfy contrast calibration demands in the equipment.
收录类别EI
语种中文
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/44389
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Huang X.,Shen X.,Ye L.,et al. Static and dynamic contrast calibration of target source for target acquisition capability detecting equipment[J]. Guangxue Xuebao/Acta Optica Sinica,2014,34(11).
APA Huang X.,Shen X.,Ye L.,Zhao Y.,&Wang S..(2014).Static and dynamic contrast calibration of target source for target acquisition capability detecting equipment.Guangxue Xuebao/Acta Optica Sinica,34(11).
MLA Huang X.,et al."Static and dynamic contrast calibration of target source for target acquisition capability detecting equipment".Guangxue Xuebao/Acta Optica Sinica 34.11(2014).
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
目标捕获能力检测装置静动态目标源对比度的(1547KB) 开放获取CC BY-ND浏览 请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Huang X.]的文章
[Shen X.]的文章
[Ye L.]的文章
百度学术
百度学术中相似的文章
[Huang X.]的文章
[Shen X.]的文章
[Ye L.]的文章
必应学术
必应学术中相似的文章
[Huang X.]的文章
[Shen X.]的文章
[Ye L.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 目标捕获能力检测装置静动态目标源对比度的标定_黄欣.caj
格式: caj
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。