CIOMP OpenIR  > 中科院长春光机所知识产出
Radiation calibration method for infrared system with large aperture and broad dynamic range
Sun Z.; Chang S.; Zhu W.
2014
发表期刊Guangxue Xuebao/Acta Optica Sinica
ISSNISBN/02532239
卷号34期号:7
摘要The existing radiation calibration for infrared system with large aperture and broad dynamic range needs huge infrared collimator, but this method has poor motility and cost much. In order to settle this question, a new calibration method basing on the amendment of inner and outer calibration is put forward. This method set a middle-high temperature cavity blackbody in infrared system, with the help of switching reflector, the cavity blackbody radiation is imported into optics system for the inner calibration on parts of system at middle-high temperature range, and an extended source blackbody is needed for the outer calibration on the whole system at middle-low temperature range. The inner and outer calibration data at common temperature range are picked up to calculate the amendatory coefficient. In the end, the whole system's radiation calibration data at the middle-high temperature range are caught by amending the inner calibration data. Combining the outer calibration data at the middle-low temperature range, the whole system's radiation calibration data at broad dynamic range are gained. Carrying through this method on an 400 mm infrared system and calculating the luminance error and temperature error, the maximal luminance error is 1.35% and the maximal temperature error is 0.76C, the results indicate that the proposed method is effective.
收录类别EI
语种中文
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/44304
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Sun Z.,Chang S.,Zhu W.. Radiation calibration method for infrared system with large aperture and broad dynamic range[J]. Guangxue Xuebao/Acta Optica Sinica,2014,34(7).
APA Sun Z.,Chang S.,&Zhu W..(2014).Radiation calibration method for infrared system with large aperture and broad dynamic range.Guangxue Xuebao/Acta Optica Sinica,34(7).
MLA Sun Z.,et al."Radiation calibration method for infrared system with large aperture and broad dynamic range".Guangxue Xuebao/Acta Optica Sinica 34.7(2014).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
大口径_宽动态范围红外测量系统辐射定标方(359KB) 开放获取CC BY-ND浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Sun Z.]的文章
[Chang S.]的文章
[Zhu W.]的文章
百度学术
百度学术中相似的文章
[Sun Z.]的文章
[Chang S.]的文章
[Zhu W.]的文章
必应学术
必应学术中相似的文章
[Sun Z.]的文章
[Chang S.]的文章
[Zhu W.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 大口径_宽动态范围红外测量系统辐射定标方法_孙志远.caj
格式: caj
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。