CIOMP OpenIR  > 中科院长春光机所知识产出
Patient specific respiratory motion modeling using a limited number of 3D lung CT images
Cui X. L.; Gao X.; Xia W.; Liu Y. C.; Liang Z. Y.
2014
发表期刊Bio-Medical Materials and Engineering
ISSNISBN/0959-2989
卷号24期号:6页码:3113-3120
摘要To build a patient specific respiratory motion model with a low dose, a novel method was proposed that uses a limited number of 3D lung CT volumes with an external respiratory signal. 4D lung CT volumes were acquired for patients with in vitro labeling on the upper abdominal surface. Meanwhile, 3D coordinates of in vitro labeling were measured as external respiratory signals. A sequential correspondence between the 4D lung CT and the external respiratory signal was built using the distance correlation method, and a 3D displacement for every registration control point in the CT volumes with respect to time can be obtained by the 4D lung CT deformable registration. A temporal fitting was performed for every registration control point displacements and an external respiratory signal in the anterior-posterior direction respectively to draw their fitting curves. Finally, a linear regression was used to fit the corresponding samples of the control point displacement fitting curves and the external respiratory signal fitting curve to finish the pulmonary respiration modeling. Compared to a B-spline-based method using the respiratory signal phase, the proposed method is highly advantageous as it offers comparable modeling accuracy and target modeling error (TME); while at the same time, the proposed method requires 70% less 3D lung CTs. When using a similar amount of 3D lung CT data, the mean of the proposed method's TME is smaller than the mean of the PCA (principle component analysis)-based methods' TMEs. The results indicate that the proposed method is successful in striking a balance between modeling accuracy and number of 3D lung CT volumes.
收录类别SCI
语种英语
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/44256
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Cui X. L.,Gao X.,Xia W.,et al. Patient specific respiratory motion modeling using a limited number of 3D lung CT images[J]. Bio-Medical Materials and Engineering,2014,24(6):3113-3120.
APA Cui X. L.,Gao X.,Xia W.,Liu Y. C.,&Liang Z. Y..(2014).Patient specific respiratory motion modeling using a limited number of 3D lung CT images.Bio-Medical Materials and Engineering,24(6),3113-3120.
MLA Cui X. L.,et al."Patient specific respiratory motion modeling using a limited number of 3D lung CT images".Bio-Medical Materials and Engineering 24.6(2014):3113-3120.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Cui-2014-Patient spe(502KB) 开放获取CC BY-ND浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Cui X. L.]的文章
[Gao X.]的文章
[Xia W.]的文章
百度学术
百度学术中相似的文章
[Cui X. L.]的文章
[Gao X.]的文章
[Xia W.]的文章
必应学术
必应学术中相似的文章
[Cui X. L.]的文章
[Gao X.]的文章
[Xia W.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Cui-2014-Patient specific res.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。