CIOMP OpenIR  > 中科院长春光机所知识产出
Experimental investigation into gas/particle flow in a down-fired 350 MWe supercritical utility boiler at different over-fire air ratios
Liu C. L.; Li Z. Q.; Jing X. J.; Xie Y. Q.; Zhang Q. H.; Zong Q. D.
2014
发表期刊Energy
ISSNISBN/0360-5442
期号64页码:771-778
摘要Gas/particle two-phase flow experiments at different over-fire air ratios were conducted using a 1:20 small-scale model of a down-fired 350 MWe superficial utility boiler designed with multiple injections and multiple staging combustion technology. The mean velocity, fluctuating velocity and particle volume flux were measured using particle dynamics anemometer measurements. None of four conditions of pulverized coal short-circuit occurred. When the over-fire air percentage was 1.9% and after the arch air flow reached the tertiary air, the position of maximum gas flow velocity of the arch secondary air and the maximum particle volume flux in the fuel-rich flow was close to and eroded the furnace hopper side wall. When the over-fire air percentage was increased to 9.6%, the position of maximum gas flow velocity of the arch secondary air and the maximum particle volume flux in the fuel-rich flow started to deviate from the hopper side wall but did not erode the furnace side wall. However, when the over-fire air percentage was 9.6%, the gas velocity of the arch air flow entering the furnace hopper was still high and the arch air flow downstream depth was too deep. Therefore, use of an over-fire air percentage greater than 19.1% was recommended. Published by Elsevier Ltd.
收录类别SCI ; EI
语种英语
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/43981
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Liu C. L.,Li Z. Q.,Jing X. J.,et al. Experimental investigation into gas/particle flow in a down-fired 350 MWe supercritical utility boiler at different over-fire air ratios[J]. Energy,2014(64):771-778.
APA Liu C. L.,Li Z. Q.,Jing X. J.,Xie Y. Q.,Zhang Q. H.,&Zong Q. D..(2014).Experimental investigation into gas/particle flow in a down-fired 350 MWe supercritical utility boiler at different over-fire air ratios.Energy(64),771-778.
MLA Liu C. L.,et al."Experimental investigation into gas/particle flow in a down-fired 350 MWe supercritical utility boiler at different over-fire air ratios".Energy .64(2014):771-778.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Liu-2014-Experimenta(990KB) 开放获取CC BY-ND浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Liu C. L.]的文章
[Li Z. Q.]的文章
[Jing X. J.]的文章
百度学术
百度学术中相似的文章
[Liu C. L.]的文章
[Li Z. Q.]的文章
[Jing X. J.]的文章
必应学术
必应学术中相似的文章
[Liu C. L.]的文章
[Li Z. Q.]的文章
[Jing X. J.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Liu-2014-Experimental investi.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。