Effect of sample position on collinear femtosecond double-pulse laser-induced breakdown spectroscopy of silicon in air
Qi H. X.; Li S. Y.; Qi Y.; Chen A. M.; Hu Z.; Huang X. R.; Jin M. X.; Ding D. J.
2014
发表期刊Journal of Analytical Atomic Spectrometry
ISSNISBN/0267-9477
卷号29期号:6页码:1105-1111
摘要A femtosecond double-pulse laser was used to induce the plasma of silicon in air. The laser wavelength was 800 nm. The interpulse delay of the femtosecond double-pulse was from -20 ps to 100 ps. During the experiment, the spectral line was fixed at the wavelength of 288.157 nm. The emission intensity was observed to lead to a significant increase by choosing the proper sample position. The range of the sample position is from 5.17 mm to 5.27 mm. And, the best sample position for the higher laser fluence was different from the position for the lower laser fluence. At the higher laser fluence, the optimized emission intensity can be obtained at either side of the best focal position for all interpulse delays of the double-pulse. The phenomena can be explained by the nonlinear propagation of the femtosecond laser pulse in air. At the lower laser fluence, the best sample position will change from one side to both sides with the increase of the interpulse delay of the double-pulse. The results showed that the effect of the sample position can be especially advantageous in the context of femtosecond double-pulse laser-induced breakdown spectroscopy. The study will lead a further improvement in the applications of the femtosecond double-pulse laser.
收录类别SCI
语种英语
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/43935
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Qi H. X.,Li S. Y.,Qi Y.,et al. Effect of sample position on collinear femtosecond double-pulse laser-induced breakdown spectroscopy of silicon in air[J]. Journal of Analytical Atomic Spectrometry,2014,29(6):1105-1111.
APA Qi H. X..,Li S. Y..,Qi Y..,Chen A. M..,Hu Z..,...&Ding D. J..(2014).Effect of sample position on collinear femtosecond double-pulse laser-induced breakdown spectroscopy of silicon in air.Journal of Analytical Atomic Spectrometry,29(6),1105-1111.
MLA Qi H. X.,et al."Effect of sample position on collinear femtosecond double-pulse laser-induced breakdown spectroscopy of silicon in air".Journal of Analytical Atomic Spectrometry 29.6(2014):1105-1111.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Qi-2014-Effect of sa(1576KB) 开放获取CC BY-ND浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Qi H. X.]的文章
[Li S. Y.]的文章
[Qi Y.]的文章
百度学术
百度学术中相似的文章
[Qi H. X.]的文章
[Li S. Y.]的文章
[Qi Y.]的文章
必应学术
必应学术中相似的文章
[Qi H. X.]的文章
[Li S. Y.]的文章
[Qi Y.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Qi-2014-Effect of sample pos.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。