CIOMP OpenIR  > 中科院长春光机所知识产出
Detection of trace microcystin-LR on a 20 MHz QCM sensor coated with in situ self-assembled MIPs
He H.; Zhou L.; Wang Y.; Li C.; Yao J.; Zhang W.; Zhang Q.; Li M.; Li H.; Dong W.-F.
2014
发表期刊Talanta
ISSNISBN/00399140
期号131页码:8-13
摘要A 20 MHz quartz crystal microbalance (QCM) sensor coated with in situ self-assembled molecularly imprinted polymers (MIPs) was presented for the detection of trace microcystin-LR (MC-LR) in drinking water. The sensor performance obtained using the in situ self-assembled MIPs was compared with traditionally synthesized MIPs on 20 MHz and normal 10 MHz QCM chip. The results show that the response increases by more than 60% when using the in situ self-assembly method compared using the traditionally method while the 20 MHz QCM chip provides four-fold higher response than the 10 MHz one. Therefore, the in situ self-assembled MIPs coated on a high frequency QCM chip was used in the sensor performance test to detect MC-LR in tap water. It showed a limit of detection (LOD) of 0.04 nM which is lower than the safety guideline level (1 nM MC-LR) of drinking water in China. The low sensor response to other analogs indicated the high specificity of the sensor to MC-LR. The sensor showed high stability and low signal variation less than 2.58% after regeneration. The lake water sample analysis shows the sensor is possible for practical use. The combination of the higher frequency QCM with the in situ self-assembled MIPs provides a good candidate for the detection of other small molecules. 2014 Elsevier B.V. All rights reserved.
收录类别EI
语种英语
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/43886
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
He H.,Zhou L.,Wang Y.,et al. Detection of trace microcystin-LR on a 20 MHz QCM sensor coated with in situ self-assembled MIPs[J]. Talanta,2014(131):8-13.
APA He H..,Zhou L..,Wang Y..,Li C..,Yao J..,...&Dong W.-F..(2014).Detection of trace microcystin-LR on a 20 MHz QCM sensor coated with in situ self-assembled MIPs.Talanta(131),8-13.
MLA He H.,et al."Detection of trace microcystin-LR on a 20 MHz QCM sensor coated with in situ self-assembled MIPs".Talanta .131(2014):8-13.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
He-2014-Detection of(1243KB) 开放获取CC BY-ND浏览 请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[He H.]的文章
[Zhou L.]的文章
[Wang Y.]的文章
百度学术
百度学术中相似的文章
[He H.]的文章
[Zhou L.]的文章
[Wang Y.]的文章
必应学术
必应学术中相似的文章
[He H.]的文章
[Zhou L.]的文章
[Wang Y.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: He-2014-Detection of trace m.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。