Study on the Absolute Spectral Irradiation Calibration Method for Far Ultraviolet Spectrometer in Remote Sensing
Yu L.; Lin G. Y.; Chen B.
2013
发表期刊Spectroscopy and Spectral Analysis
ISSNISBN/1000-0593
卷号33期号:1
摘要The present paper studied spectral irradiation responsivities calibration method which can be applied to the far ultraviolet spectrometer for upper atmosphere remote sensing. It is difficult to realize the calibration for far ultraviolet spectrometer for many reasons. Standard instruments for far ultraviolet waveband calibration are few, the degree of the vacuum experiment system is required to be high, the stabilities of the experiment are hardly maintained, and the limitation of the far ultraviolet waveband makes traditional diffuser and the integrating sphere radiance calibration method difficult to be used. To solve these problems, a new absolute spectral irradiance calibration method was studied, which can be applied to the far ultraviolet calibration. We build a corresponding special vacuum experiment system to verify the calibration method. The light source system consists of a calibrated deuterium lamp, a vacuum ultraviolet monochromater and a collimating system. We used the calibrated detector to Obtain the irradiance responsivities of it. The three instruments compose the calibration irradiance source. We used the "calibration irradiance source" to illuminate the spectrometer prototype and obtained the spectral irradiance responsivities. It realized the absolute spectral irradiance calibration for the far ultraviolet spectrometer utilizing the calibrated detector. The absolute uncertainty of the calibration is 7.7%. The method is significant for the ground irradiation calibration of the far ultraviolet spectrometer in upper atmosphere remote sensing.
收录类别SCI
语种中文
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/40871
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Yu L.,Lin G. Y.,Chen B.. Study on the Absolute Spectral Irradiation Calibration Method for Far Ultraviolet Spectrometer in Remote Sensing[J]. Spectroscopy and Spectral Analysis,2013,33(1).
APA Yu L.,Lin G. Y.,&Chen B..(2013).Study on the Absolute Spectral Irradiation Calibration Method for Far Ultraviolet Spectrometer in Remote Sensing.Spectroscopy and Spectral Analysis,33(1).
MLA Yu L.,et al."Study on the Absolute Spectral Irradiation Calibration Method for Far Ultraviolet Spectrometer in Remote Sensing".Spectroscopy and Spectral Analysis 33.1(2013).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
大气遥感远紫外光谱仪绝对光谱辐照度响应度(366KB) 开放获取CC BY-NC-ND浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Yu L.]的文章
[Lin G. Y.]的文章
[Chen B.]的文章
百度学术
百度学术中相似的文章
[Yu L.]的文章
[Lin G. Y.]的文章
[Chen B.]的文章
必应学术
必应学术中相似的文章
[Yu L.]的文章
[Lin G. Y.]的文章
[Chen B.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 大气遥感远紫外光谱仪绝对光谱辐照度响应度定标方法研究_于磊.pdf
格式: Adobe PDF
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。