CIOMP OpenIR  > 中科院长春光机所知识产出
Sensitivity analysis of thermal design parameters for focal plane assembly in a space spectral imaging instrument
Guo L.; Wu Q. W.; Yan C. X.
2013
发表期刊Heat and Mass Transfer
ISSNISBN/0947-7411
卷号49期号:3
摘要There are deviations between real parameters and thermal design parameters on thermophysical attribute of focal plane assembly (FPA). The parameters are difficult to be determined accurately and the thermal design scheme will be affected with the values of the parameters. The thermal design problem of FPA is described by means of system sensitivity theory. The in-orbit heat balance equations are established, and the thermal design parameters, which might affect the temperature distribution of the FPA, are given. As an example, the sensitivity of thermal design parameters is analyzed for a FPA in a space spectral imaging instrument. A basis to determine the structural and thermophysical parameters for FPA is gotten, furthermore, an analytical method is provided for reliability validation of thermal design and operating reliability on orbit. It is shown that contact heat-transfer coefficient between mounted surfaces and surface emissivity are the main parameters affecting mean temperature of Charge converse device (CCD). The power of the inner heat source, thermal conductivity and inner contact heat-transfer coefficient are the primary parameters affecting temperature difference between CCD and the heat-transfer block. The thermal test is set up, and it is illuminated that the sensitivity analysis strategy based on the thermal design scheme is effective and feasible.
收录类别SCI ; EI
语种英语
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/40843
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Guo L.,Wu Q. W.,Yan C. X.. Sensitivity analysis of thermal design parameters for focal plane assembly in a space spectral imaging instrument[J]. Heat and Mass Transfer,2013,49(3).
APA Guo L.,Wu Q. W.,&Yan C. X..(2013).Sensitivity analysis of thermal design parameters for focal plane assembly in a space spectral imaging instrument.Heat and Mass Transfer,49(3).
MLA Guo L.,et al."Sensitivity analysis of thermal design parameters for focal plane assembly in a space spectral imaging instrument".Heat and Mass Transfer 49.3(2013).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Guo-2013-Sensitivity(999KB) 开放获取CC BY-NC-ND浏览 请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Guo L.]的文章
[Wu Q. W.]的文章
[Yan C. X.]的文章
百度学术
百度学术中相似的文章
[Guo L.]的文章
[Wu Q. W.]的文章
[Yan C. X.]的文章
必应学术
必应学术中相似的文章
[Guo L.]的文章
[Wu Q. W.]的文章
[Yan C. X.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Guo-2013-Sensitivity analysis.pdf
格式: Adobe PDF
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。