Changchun Institute of Optics,Fine Mechanics and Physics,CAS
Optimum Design of Imaging Spectrometer Based on Toroidal Uniform-Line-Spaced (TULS) Spectrometer | |
Xue Q. S.; Wang S. R. | |
2013 | |
发表期刊 | Spectroscopy and Spectral Analysis |
ISSN | ISBN/1000-0593 |
卷号 | 33期号:5 |
摘要 | Based on the geometrical aberration theory, a optimum-design method for designing an imaging spectrometer based on toroidal uniform grating spectrometer is proposed. To obtain the best optical parameters, twice optimization is carried out using genetic algorithm(GA) and optical design software ZEMAX. A far-ultraviolet(FUV) imaging spectrometer is designed using this method. The working waveband is 110 similar to 180 nm, the slit size is 50 mu mX5 mm, and the numerical aperture is 0. 1. Using ZEMAX software, the design result is analyzed and evaluated. The results indicate that the MTF for different wavelengths is higher than 0. 7 at Nyquist frequency 10 1p . mm(-1), and the RMS spot radius is less than 14 mu m. The good imaging quality is achieved over the whole working waveband, the design requirements of spatial resolution 0. 5 mrad and spectral resolution 0. 6 nm are satisfied. It is certificated that the optimum-design method proposed in this paper is feasible. This method can be applied in other waveband, and is an instruction method for designing grating-dispersion imaging spectrometers. |
收录类别 | SCI |
语种 | 英语 |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/40802 |
专题 | 中科院长春光机所知识产出 |
推荐引用方式 GB/T 7714 | Xue Q. S.,Wang S. R.. Optimum Design of Imaging Spectrometer Based on Toroidal Uniform-Line-Spaced (TULS) Spectrometer[J]. Spectroscopy and Spectral Analysis,2013,33(5). |
APA | Xue Q. S.,&Wang S. R..(2013).Optimum Design of Imaging Spectrometer Based on Toroidal Uniform-Line-Spaced (TULS) Spectrometer.Spectroscopy and Spectral Analysis,33(5). |
MLA | Xue Q. S.,et al."Optimum Design of Imaging Spectrometer Based on Toroidal Uniform-Line-Spaced (TULS) Spectrometer".Spectroscopy and Spectral Analysis 33.5(2013). |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
基于超环面均匀线距光栅的成像光谱仪优化设(701KB) | 开放获取 | CC BY-NC-ND | 浏览 下载 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Xue Q. S.]的文章 |
[Wang S. R.]的文章 |
百度学术 |
百度学术中相似的文章 |
[Xue Q. S.]的文章 |
[Wang S. R.]的文章 |
必应学术 |
必应学术中相似的文章 |
[Xue Q. S.]的文章 |
[Wang S. R.]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论