Modified Dyson imaging spectrometer with an aspheric grating surface
Xue Q.
2013
发表期刊Optics Communications
ISSNISBN/00304018
期号308
摘要A broadband, aberration-corrected Dyson arrangement with an aspheric grating surface is proposed. An aspheric grating surface is used to correct spherical aberration resulted from the air gap between the focal plane and the rear surface of Dyson lens. The principle and the method of aberration correction are described in detail. We compare the performance of this modified Dyson arrangement with that of the Dyson arrangement using a spherical grating surface by using a practical Dyson imaging spectrometer example. 2013 Elsevier B.V.
收录类别SCI ; EI
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/40755
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Xue Q.. Modified Dyson imaging spectrometer with an aspheric grating surface[J]. Optics Communications,2013(308).
APA Xue Q..(2013).Modified Dyson imaging spectrometer with an aspheric grating surface.Optics Communications(308).
MLA Xue Q.."Modified Dyson imaging spectrometer with an aspheric grating surface".Optics Communications .308(2013).