CIOMP OpenIR  > 中科院长春光机所知识产出
A Dye Densitometry Analysis Method for Noninvasive Measurement of Cardiac Output Based on NIRS
Lu M. M.; Wang H. X.; Liu G. D.; Xin G. J.; Yu Y.; Zha Y. T.
2013
发表期刊Spectroscopy and Spectral Analysis
ISSNISBN/1000-0593
卷号33期号:12
摘要Currently, there exist technology problems in cardiac output (CO) parameter detection clinically, such as invasive and complex operation, as well as possibility of infection and death for patients. In order to solve these problems, a noninvasive and continuous method based on NIRS for CO detection was presented. In this way, the concentration changing of indocyanine green (ICG) dye in the patient's arterial blood was dynamically measured and analyzed, so that the CO could be noninvasively and continuously measured according to the characteristic parameters of dye densitometry curve. While the ICG dye was injected into the patient's body by the median cubital vein, block of photoelectric pulse dye densitometry measurement system as the lower machine acquired pulse wave data and uploaded the data to upper computer. In the scheme, two specialized light sources of LED at 940 and 805 nm were used to capture the signals of sufferer's fingertip pulse wave synchronously and successively. The CO value could then be successfully calculated through drawing complete ICG concentration variation of dye dilution and excretion process and computing mean transmission time (MTT) by upper computer. Compared with the "gold standard" method of thermodilution, the maximum relative error of this method was below 9. 76%, and the mean relative error was below 4. 39%. The result indicates that the method can be used as a kind of convenient operation, noninvasive and continuous solution for clinical CO measurement.
收录类别SCI
语种中文
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/40620
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Lu M. M.,Wang H. X.,Liu G. D.,et al. A Dye Densitometry Analysis Method for Noninvasive Measurement of Cardiac Output Based on NIRS[J]. Spectroscopy and Spectral Analysis,2013,33(12).
APA Lu M. M.,Wang H. X.,Liu G. D.,Xin G. J.,Yu Y.,&Zha Y. T..(2013).A Dye Densitometry Analysis Method for Noninvasive Measurement of Cardiac Output Based on NIRS.Spectroscopy and Spectral Analysis,33(12).
MLA Lu M. M.,et al."A Dye Densitometry Analysis Method for Noninvasive Measurement of Cardiac Output Based on NIRS".Spectroscopy and Spectral Analysis 33.12(2013).
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
基于近红外光谱实现心输出量无创检测的色素(1345KB) 开放获取CC BY-NC-ND浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Lu M. M.]的文章
[Wang H. X.]的文章
[Liu G. D.]的文章
百度学术
百度学术中相似的文章
[Lu M. M.]的文章
[Wang H. X.]的文章
[Liu G. D.]的文章
必应学术
必应学术中相似的文章
[Lu M. M.]的文章
[Wang H. X.]的文章
[Liu G. D.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 基于近红外光谱实现心输出量无创检测的色素谱分析方法_卢蒙蒙.pdf
格式: Adobe PDF
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。