摘要 | A passive through hole microvalve is proposed to stop the capillary-driven flow in microchannels with small static contact angle (theta(s) < 45 degrees). Its gating condition on regulating flow is derived based on contact line theory. Using numerical simulations in certain limits and some experiments, we investigated the valve performance of a few different valve designs. A kind of converging through hole microvalve is found which can stop the relative faster capillary flow and is easier to fabricate and integrate. It is shown that allowable flow velocity for DI water could reach 0.5 m/s, and the height of microvalve could be as short as to 20 mu m. (C) 2010 Elsevier B.V. All rights reserved. |
收录类别 | SCI ; EI |
语种 | 英语 |
文献类型 | 期刊论文 |
条目标识符 | http://ir.ciomp.ac.cn/handle/181722/26091 |
专题 | 中科院长春光机所知识产出 |
推荐引用方式 GB/T 7714 | Du X.,Zhang P.,Liu Y. S.,et al. A passive through hole microvalve for capillary flow control in microfluidic systems[J]. Sensors and Actuators a-Physical,2011,165(2):288-293. |
APA | Du X.,Zhang P.,Liu Y. S.,&Wu Y. H..(2011).A passive through hole microvalve for capillary flow control in microfluidic systems.Sensors and Actuators a-Physical,165(2),288-293. |
MLA | Du X.,et al."A passive through hole microvalve for capillary flow control in microfluidic systems".Sensors and Actuators a-Physical 165.2(2011):288-293. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Du-2011-A passive th(869KB) | 开放获取 | -- | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论