摘要Spectral curvature destroys the co-registration of the spectra measured by dispersion imaging spectrometer. Using interpolation to re-sample the measured spectra at the non-offset mid-wavelengths can mitigate the spectral misregistration. It is very important to select an optimum interpolation method. The performances of six common interpolation methods are evaluated by comparing the residual errors in the corrected spectral radiance. The results indicate that, four-point cubic Lagrange interpolation and cubic spline interpolation are better than other four interpolation methods (linear Interpolation, three points quadratic polynomial interpolation, five points four-order Lagrange interpolation and cubic Hermite interpolation). For spectral offset of 10% Delta lambda(Delta lambda=5 nm), the normalized errors in measured spectral radiance is PV=0. 06, that is reduced to PV<0. 022 after interpolation with cubic Lagrange interpolation or cubic spline interpolation, but for other four methods they are PV> 0. 035. Furthermore, for lower spectral resolution (Delta lambda>5 nm), cubic Lagrange interpolation is a little better than cubic spline interpolation; while for higher spectral resolution (Delta lambda<5 nm), cubic spline interpolation is a little better.
收录类别SCI
语种中文
文献类型期刊论文
条目标识符http://ir.ciomp.ac.cn/handle/181722/25571
专题中科院长春光机所知识产出
推荐引用方式
GB/T 7714
Chen X.,Xiang Y.,Feng Y. T.. Selection of Interpolation Methods Used to Mitigate Spectral Misregistration of Imaging Spectrometers[J]. Spectroscopy and Spectral Analysis,2011,31(4):1147-1150.
APA Chen X.,Xiang Y.,&Feng Y. T..(2011).Selection of Interpolation Methods Used to Mitigate Spectral Misregistration of Imaging Spectrometers.Spectroscopy and Spectral Analysis,31(4),1147-1150.
MLA Chen X.,et al."Selection of Interpolation Methods Used to Mitigate Spectral Misregistration of Imaging Spectrometers".Spectroscopy and Spectral Analysis 31.4(2011):1147-1150.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
成像光谱仪辐射测量一致性校正中插值方法选(437KB) 开放获取--浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Chen X.]的文章
[Xiang Y.]的文章
[Feng Y. T.]的文章
百度学术
百度学术中相似的文章
[Chen X.]的文章
[Xiang Y.]的文章
[Feng Y. T.]的文章
必应学术
必应学术中相似的文章
[Chen X.]的文章
[Xiang Y.]的文章
[Feng Y. T.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 成像光谱仪辐射测量一致性校正中插值方法选择.caj
格式: caj
此文件暂不支持浏览
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。